FITTING THE HOB
The hob is equipped with a special seal to avoid any infiltration of liquid into the unit. To apply this seal
correctly, please follow the instructions given below carefully:
•
Remove all the mobile parts of the hob.
•
Turn the hob upside down and place the adhesive putty “E” (fig.
14) under the edge of the hob so that perfectly matches the outer
perimeter edge of the glass. The ends of the strips must match
without overlapping.
•
Stick the putty to the glass evenly and securely, using your fingers
to press it into place.
•
For the gas: fix the hob with the proper hooks “S” and fit the
prominent part into the porthole “H” on the bottom; turn the
screw “F” until the hook “S” stick on the top (fig. 15).
•
For the induction: position the hob in the hole in the unit and
fasten it in place using the appropriate screws “F” of the fastening
hooks “G” (see fig. 15/A).
•
In order to avoid accidental contact with the surface of the box of
the overheated hob during use, it is necessary to install a wooden
divider at a minimum distance of 120 mm from the top, fastening
it in place with screws (fig. 12).
CAUTION:
In case of hotplate glass breakage:
•
Shut immediately off all burners and any electrical heating element and isolate the appliance from the
power supply.
•
Do not touch the appliance surface
•
Do not use the appliance.
POSITIONING HOOKS
FIG. 14
gas
induction
hook A (gas)
hook B (induction)
FIG. 15/A
FIG. 15
Summary of Contents for KIGH 6422 CI B
Page 1: ...INSTRUKCJA OBS UGI P YTY INDUKCYJNO GAZOWEJ KIGH 6422 CI B www kernau com...
Page 2: ......
Page 29: ...INSTRUCTION MANUAL OF KITCHEN HOB KIGH 6422 CI B www kernau com...
Page 30: ......
Page 55: ...N VOD K OBSLUZE INDUK N HO A PLYNOV HO PANELU KIGH 6422 CI B www kernau com...
Page 56: ......
Page 81: ...KIGH 6422 CI B www kernau com...
Page 82: ...UA 82...
Page 84: ...UA 84 8 8 1...
Page 87: ...UA 87 FIG 3 FIG 4 FIG 5 1 FIG 2 OFF Reduced rate position 1 3 4 5 3 4 5...
Page 88: ...UA 88 20 50 1 10...
Page 89: ...UA 89 1 9 9 Booster P 10 9 1 99 5 0 3 1 CHILD LOCK Child Lock 3 2 0 5 0 0...
Page 90: ...UA 90 BOOSTER 6 14 5 1200 1600 7 21 1500 2000 1 1 3 4 8 5 9 9 P FIG 6 6 95 C...
Page 91: ...UA 91 FIG 7 7 7 H OFF 7 1 20...
Page 92: ...UA 92 INDUCTION 14 5 9 21 13 1 10 2 10 3 10 4 10 5 10 6 10 7 10 8 10 9 3...
Page 93: ...UA 93 4 8 8 8 T 8 A B C 8 A 8 B FIG 8 FIG 8 B FIG 8 A 8 8 A 8 B...
Page 95: ...UA 95 12 3 FIG 12 FIG 13 FIG 11 13 11 12...
Page 97: ...UA 97 90 C 150 oC 20 3 100 2 3 4 5 EN 10226 2...
Page 98: ...UA 98 2 EN 10226 CE 2016 426 90 C C 16 16...
Page 99: ...UA 99 L N 90 C 3 ECM LVD RoHS ERP FIG 16 gas induction 16...
Page 100: ...UA 100 220 240 B B H05 RR F 3x0 75mm2 A H07 RN F H05 VV F 3x1 5 mm2 24...
Page 101: ...UA 101 1 22 22 22 D 22 22 6 FIG 22 A FIG 22 E G20 B P G30 G31 22 22 A FIG 23 E G20 B A 23 23...
Page 103: ...UA 103 7 CM BOOSTER 14 5 1200 1600 21 0 1200 2000 2 60 220 240 50 3600 FIG 24 24...
Page 104: ...UA 104 8 1 1 ECO ON OFF r r 1 ON Power U OFF H C ON Power OFF H C ON Power OFF H H...
Page 105: ...UA 105 F 0 5 OFF F5 OFF F1 OFF F2 1 OFF F7 2 OFF F8 OFF F9 OFF F3 OFF F4 OFF F6...
Page 106: ...UA 106 F EEPROM 0 5 F0 ON OFF FA ON OFF FC FE Ft 90 C Fc EEPROM FH A D FJ FL A D FU...
Page 108: ...www kernau com...