NX-900
64
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations /
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
5. High RSSI
at
–80dBm
*8
[Analog
Narrow]
1) Adj item: [An HRSSI]
Adjust:
[
✳✳✳
]
2) Adj item:
[AnL
HRSSI]
→
[AnC
HRSSI]
→
[AnH
HRSSI]
SSG
output:
–80dBm
(22.4µV)
(MOD: 1kHz/±1.5kHz)
1) Adj item: [High
RSSI (Narrow)]
2) Adj item: [Low],
[Center], [High]
SSG
output:
–80dBm
(22.4µV)
(MOD: 1kHz/±1.5kHz)
SSG
AF VTVM
Oscilloscope
ANT
Ext.SP
connector
[Panel tuning mode]
After input signal
from SSG, press
[ ] key to store the
adjustment value.
[PC test mode]
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.
[Analog
Wide 4k]
1) Adj item: [As HRSSI]
Adjust:
[
✳✳✳
]
2) Adj item:
[AsL
HRSSI]
→
[AsC
HRSSI]
→
[AsH
HRSSI]
SSG
output:
–80dBm
(22.4µV)
(MOD: 1kHz/±2.4kHz)
1) Adj item: [High
RSSI (Wide 4k)]
2) Adj item: [Low],
[Center], [High]
SSG
output:
–80dBm
(22.4µV)
(MOD: 1kHz/±2.4kHz)
[Analog
Wide 5k]
1) Adj item: [Aw HRSSI]
Adjust:
[
✳✳✳
]
2) Adj item:
[AwL
HRSSI]
→
[AwC
HRSSI]
→
[AwH
HRSSI]
SSG
output:
–80dBm
(22.4µV)
(MOD: 1kHz/±3kHz)
1) Adj item: [High
RSSI (Wide 5k)]
2) Adj item: [Low],
[Center], [High]
SSG
output:
–80dBm
(22.4µV)
(MOD: 1kHz/±3kHz)
[NXDN
Very
Narrow]
1) Adj item: [Nv HRSSI]
Adjust:
[
✳✳✳
]
2) Adj item:
[NvL
HRSSI]
→
[NvC
HRSSI]
→
[NvH
HRSSI]
SSG
output:
–80dBm
(22.4µV)
(MOD: 1kHz/±1.5kHz)
1) Adj item: [High
RSSI (Very Narrow)]
2) Adj item: [Low],
[Center], [High]
SSG
output:
–80dBm
(22.4µV)
(MOD: 1kHz/±1.5kHz)
Adjust with the ana-
log signal.
*8: Because “RSSI at –80dBm adjust” of NXDN Narrow is adjusted by adjusting “RSSI at –80dBm adjust [Analog Narrow]”, it is not necessary to
adjust “RSSI at –80dBm adjust” of NXDN Narrow.
Summary of Contents for NEXEDGE NX-900
Page 105: ...NX 900 105 MEMO ...