ADJUSTMENT
■
Necessary Deviation adjustment item for each signaling and mode
The following shows the necessary adjustment items for each signaling deviation. Please read the following table like the following example. In the
case of the signaling “QT (Wide 5k)”, this signaling is composed of three elements [Balance, Maximum Deviation (Analog Wide 5k) and QT Deviation
(Wide 5k)]. Please adjust Balance and Maximum Deviation (Analog Wide 5k) before adjusting QT Deviation (Wide 5k).
Mode
Signaling
Necessary adjustment and order
Wide 5k
Wide 4k
Narrow
Very Narrow
Analog
Audio
Step1. Balance adjust
Step2. Maximum Deviation
(Analog
Wide
5k)
Step1. Balance adjust
Step2. Maximum Deviation
(Analog
Wide
4k)
Step1.Balance adjust
Step2. Maximum Deviation
(Analog
Narrow)
-
QT
Step1. Balance adjust
Step2. Maximum Deviation
(Analog
Wide
5k)
Step3. QT Deviation
(Analog
Wide
5k)
Step1. Balance adjust
Step2. Maximum Deviation
(Analog
Wide
4k)
Step3. QT Deviation
(Analog
Wide
4k)
Step1. Balance adjust
Step2. Maximum Deviation
(Analog
Narrow)
Step3. QT Deviation
(Analog
Narrow)
-
DQT
Step1. Balance adjust
Step2. Maximum Deviation
(Analog
Wide
5k)
Step3. DQT Deviation
(Analog
Wide
5k)
Step1. Balance adjust
Step2. Maximum Deviation
(Analog
Wide
4k)
Step3. DQT Deviation
(Analog
Wide
4k)
Step1. Balance adjust
Step2. Maximum Deviation
(Analog
Narrow)
Step3. DQT Deviation
(Analog
Narrow)
-
LTR
Step1. Balance adjust
Step2. Maximum Deviation
(Analog
Wide
5k)
Step3. LTR Deviation
(Analog
Wide
5k)
Step1. Balance adjust
Step2. Maximum Deviation
(Analog
Wide
4k)
Step3. LTR Deviation
(Analog
Wide
4k)
Step1. Balance adjust
Step2. Maximum Deviation
(Analog
Narrow)
Step3. LTR Deviation
(Analog
Narrow)
-
DTMF
Step1. Balance adjust
Step2. Maximum Deviation
(Analog
Wide
5k)
Step3. DTMF Deviation
(Analog
Wide
5k)
Step1. Balance adjust
Step2. Maximum Deviation
(Analog
Wide
4k)
Step3. DTMF Deviation
(Analog
Wide
4k)
Step1. Balance adjust
Step2. Maximum Deviation
(Analog
Narrow)
Step3. DTMF Deviation
(Analog
Narrow)
-
MSK
(FleetSync)
Step1. Balance adjust
Step2. Maximum Deviation
(Analog
Wide
5k)
Step3. MSK Deviation
(Analog
Wide
5k)
Step1. Balance adjust
Step2. Maximum Deviation
(Analog
Wide
4k)
Step3. MSK Deviation
(Analog
Wide
4k)
Step1. Balance adjust
Step2. Maximum Deviation
(Analog
Narrow)
Step3. MSK Deviation
(Analog
Narrow)
-
NXDN
Audio
-
-
Step1. Balance adjust
Step2. Maximum Deviation
(NXDN
Narrow)
Step1. Balance adjust
Step2. Maximum Deviation
(NXDN
Very
Narrow)
CWID
-
-
-
Step1. Balance adjust
Step2. Maximum Deviation
(Analog
Narrow)
Step3. CW ID Deviation
(NXDN
Very
Narrow)
• Balance is common with all the above deviation adjustments. If Balance (Transmitter Section 5) has already adjusted, please skip Step1 and adjust from
Step2.
• Maximum Deviation (Analog Wide 5k/Wide 4k/Narrow) is common with all the analog signaling deviations and CWID Deviation (NXDN Very Narrow). If Bal-
ance and Maximum Deviation (Analog Wide 5k/Wide 4k/Narrow) (Transmitter Section 7) have already adjusted, please skip Step2 and adjust from Step3.