NX-900
57
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations /
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
Maximum
Deviation
(Analog)
*3
[Wide
5k]
1) Adj item: [Aw ADEV]
Adjust:
[
✳✳✳✳
]
2) Adj item:
[AnL
ADEV]
→
[AnH
ADEV]
→
[AnL ADEV] (TA)
→
[AnH ADEV] (TA)
Adjust:
[
✳✳✳✳
]
PTT:
ON
Press [ ] key to store
the adjustment value.
1) Adj item: [Maximum
Deviation (Analog
Wide 5k)]
2) Adj item: [Low],
[High], [Low (TA)],
[High (TA)]
PTT:
Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
Deviation
meter
Oscilloscope
ANT
[Panel
tuning
mode]
[ ],[ ]
[PC test
mode]
[ ],[ ]
4200Hz
Write the value as
followings.
498 (Reference
value)
Deviation meter
LPF: 15kHz
HPF: OFF
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press
[Transmit] button
4150~4250Hz
[PC test mode]
Press [Apply All]
button to store the
adjustment value
after all adjustment
point was adjusted.
*3: Refer to the “Necessary Deviation adjustment item for each signaling and mode” table on page 60.
Regarding Maximum Deviation (Analog), it is common with the adjustment of all analog signalings.
8. QT
Deviation
*4
[Narrow]
1) Adj item: [An QT]
Adjust:
[
✳✳✳✳
]
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT:
ON
Press [ ] key to store
the adjustment value.
1) Adj item: [QT Devia-
tion (Narrow)]
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT:
Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
Deviation
meter
Oscilloscope
ANT
[Panel
tuning
mode]
[ ],[ ]
[PC test
mode]
[ ],[ ]
Write the value as
followings.
513 (Reference
value)
0.30~0.40kHz
[Wide 4k]
1) Adj item: [As QT]
Adjust:
[
✳✳✳✳
]
PTT:
ON
Press [ ] key to store
the adjustment value.
1) Adj item: [QT Devia-
tion (Wide 4k)]
PTT:
Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
0.55~0.65kHz
[Wide 5k]
1) Adj item: [Aw QT]
Adjust:
[
✳✳✳✳
]
PTT:
ON
Press [ ] key to store
the adjustment value.
1) Adj item: [QT Devia-
tion (Wide 5k)]
PTT:
Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
0.70~0.80kHz
9. DQT
Deviation
*4
[Narrow]
1) Adj item: [An DQT]
Adjust:
[
✳✳✳✳
]
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT:
ON
Press [ ] key to store
the adjustment value.
1) Adj item: [DQT
Deviation
(Narrow)]
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT:
Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
Write the value as
followings.
430 (Reference
value)
0.30~0.40kHz
Summary of Contents for NEXEDGE NX-900
Page 105: ...NX 900 105 MEMO ...
Page 106: ...NX 900 106 MEMO ...