ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations /
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
DQT
Deviation
*4
[Wide
4k]
1) Adj item: [As DQT]
Adjust:
[
✳✳✳✳
]
PTT:
ON
Press [ ] key to store
the adjustment value.
1) Adj item: [DQT De-
viation (Wide 4k)]
PTT:
Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
Deviation
meter
Oscilloscope
ANT
[Panel
tuning
mode]
[ ],[ ]
[PC test
mode]
[ ],[ ]
Write the value as
followings.
430 (Reference
value)
0.55~0.65kHz
[Wide 5k]
1) Adj item: [Aw DQT]
Adjust:
[
✳✳✳✳
]
PTT:
ON
Press [ ] key to store
the adjustment value.
1) Adj item: [DQT De-
viation (Wide 5k)]
PTT:
Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
0.70~0.80kHz
10. LTR
Deviation
*4
[Narrow]
1) Adj item: [An LTR]
Adjust:
[
✳✳✳✳
]
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT:
ON
Press [ ] key to store
the adjustment value.
1) Adj item: [LTR De-
viation (Narrow)]
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT:
Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
Write the value as
followings.
465 (Reference
value)
0.65~0.85kHz
[Wide 4k]
1) Adj item: [As LTR]
Adjust:
[
✳✳✳✳
]
PTT:
ON
Press [ ] key to store
the adjustment value.
1) Adj item: [LTR De-
viation (Wide 4k)]
PTT:
Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
Write the value as
followings.
523 (Reference
value)
0.80~1.00kHz
[Wide 5k]
1) Adj item: [Aw LTR]
Adjust:
[
✳✳✳✳
]
PTT:
ON
Press [ ] key to store
the adjustment value.
1) Adj item: [LTR De-
viation (Wide 5k)]
PTT:
Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
Write the value as
followings.
465 (Reference
value)
0.90~1.10kHz
11. DTMF
Deviation
*4
[Narrow]
1) Adj item: [An DTMF]
Adjust:
[
✳✳✳✳
]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
ON
Press [ ] key to store
the adjustment value.
1) Adj item: [DTMF
Deviation (Narrow)]
Deviation
meter
LPF: 15kHz
HPF: OFF
PTT:
Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
Write the value as
followings.
650 (Reference
value)
1.40~1.60kHz