ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations /
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
Maximum
Deviation
(NXDN) *3
[Very
Narrow]
1) Adj item: [Nv NDEV]
Adjust:
[
✳✳✳✳
]
2) Adj item:
[NvL
NDEV]
→
[NvH
NDEV]
→
[NvL NDEV] (TA)
→
[NvH NDEV] (TA)
Adjust:
[
✳✳✳✳
]
PTT:
ON
Press [ ] key to store
the adjustment value.
1) Adj item: [Maximum
Deviation (NXDN
Very Narrow)]
2) Adj item: [Low],
[High], [Low (TA)],
[High (TA)]
PTT:
Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
Deviation
meter
Oscilloscope
ANT
[Panel
tuning
mode]
[ ],[ ]
[PC test
mode]
[ ],[ ]
1337Hz
Write the value as
followings.
484 (Reference
value)
1331~1363Hz
[PC test mode]
Press [Apply All]
button to store the
adjustment value
after all adjustment
point was adjusted.
7. Maximum
Deviation
(Analog)
*3
[Narrow]
1) Adj item: [An ADEV]
Adjust:
[
✳✳✳✳
]
Deviation
meter
LPF: 15kHz
HPF: OFF
2) Adj item:
[AwL
ADEV]
→
[AwH
ADEV]
→
[AwL ADEV] (TA)
→
[AwH ADEV] (TA)
Adjust:
[
✳✳✳✳
]
PTT:
ON
Press [ ] key to store
the adjustment value.
1) Adj item: [Maximum
Deviation (Analog
Narrow)]
Deviation
meter
LPF: 15kHz
HPF: OFF
2) Adj item: [Low],
[High], [Low (TA)],
[High (TA)]
PTT:
Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
2100Hz
Write the value as
followings.
492 (Reference
value)
Deviation meter
LPF: 15kHz
HPF: OFF
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press
[Transmit] button
2050~2150Hz
[PC test mode]
Press [Apply All]
button to store the
adjustment value
after all adjustment
point was adjusted.
[Wide 4k]
1) Adj item: [As ADEV]
Adjust:
[
✳✳✳✳
]
2) Adj item:
[AsL
ADEV]
→
[AsH
ADEV]
→
[AsL ADEV] (TA)
→
[AsH ADEV] (TA)
Adjust:
[
✳✳✳✳
]
PTT:
ON
Press [ ] key to store
the adjustment value.
1) Adj item: [Maximum
Deviation (Analog
Wide 4k)]
2) Adj item: [Low],
[High], [Low (TA)],
[High (TA)]
PTT:
Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
3360Hz
Write the value as
followings.
496 (Reference
value)
Deviation meter
LPF: 15kHz
HPF: OFF
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press
[Transmit] button
3310~3410Hz
[PC test mode]
Press [Apply All]
button to store the
adjustment value
after all adjustment
point was adjusted.