NX-900
45
■
Frequency and Signaling
The transceiver has been adjusted for the frequencies
shown in the following table. When required, readjust them
following the adjustment procedure to obtain the frequen-
cies you want in actual operation.
• Test frequency
CH
RX (MHz)
TX (MHz)
1
851.050000
806.050000
2
860.050000
815.050000
3
869.950000
824.950000
4
851.550000
806.550000
5
860.550000
815.550000
6
869.450000
824.450000
7~16
-
-
• Analog mode signaling
No.
RX
TX
1
None
None
2
None
100Hz Square Wave
3
LTR Data :
AREA=0, GOTO=12
HOME=12
ID=47, FREE=25
LTR Data :
AREA=0, GOTO=12
HOME=12
ID=47, FREE=25
4
QT: 67.0Hz
QT: 67.0Hz
5
QT: 151.4Hz
QT: 151.4Hz
6
QT: 210.7Hz
QT: 210.7Hz
7
QT: 254.1Hz
QT: 254.1Hz
8
DQT: D023N
DQT: D023N
9
DQT: D754I
DQT: D754I
10
DTMF: 159D
DTMF: 159D
11
None
DTMF Code 9
15
None
MSK
16
MSK
MSK
• NXDN mode signaling
No.
RX
TX
1
RAN1
RAN1
2
None
PN9
3
RAN1
Maximum deviation pattern
7
None
FSW + PN9
(PC test mode only)
RAN: Radio Access Number
PN9: Pseudo-Random Pattern (For production only)
Panel Tuning Mode
■
Preparations for tuning the transceiver
Before attempting to tune the transceiver, connect the
unit to a suitable power supply.
Whenever the transmitter is turned, the unit must be
connected to a suitable dummy load (i.e. power meter).
The speaker output connector must be terminated with
a 4
Ω
dummy load and connected to an AC voltmeter and an
audio distortion meter or a SINAD measurement meter at all
times during tuning.
■
Transceiver tuning (To enter tuning mode)
To enter tuning mode, press the [ ] key while the trans-
ceiver is in test mode. Use the [ ] key to write tuning data
through tuning modes, and the [ ]/[ ] key to adjust tuning
requirements (1 to 4096 appears on the LCD).
Use the [
] key to select the adjustment item through
tuning modes. Use the [ ] key to adjust 2, 3 or 4 reference
level adjustments, and use the [ ] key to switch between
Wide 5k/Wide 4k/Narrow/Very narrow.
• LCD display in panel tuning mode
Proper value guide
(When the frequency
adjustment is necessary,
▼
or
▲
is displayed.)
Adjustment point
L,C,H
Adjustment value
(1~4096)
Adjustment item
Aw: Analog wide 5k mode
As: Analog wide 4k mode
An: Analog narrow mode
Nn: NXDN narrow mode
Nv: NXDN very narrow mode
CV voltage, AD value, etc
Main LCD display
Sub LCD display
C
Aw
NT R
2 5 6
2 . 6
Talk Around
■
Key operation
Key
Function
Push
Hold (1 second)
[ ] / [ ]
Adjustment value up/down Continuation up/down
[ ] / [ ]
Volume up/down
Continuation up/down
[ ]
Auto adjustment start
-
[ ]
Wide 5k/Wide 4k/Narrow/
Very narrow
-
[ ]
Shift to panel test mode
-
[ ]
To enter 2, 3 or 4 refer-
ence level adjustments
-
[ ]
Writes the adjustment
value
-
[
]
Go to next adjustment item Back to last adjustment item
Microphone key
[PTT]
Transmit
-
[0] to [9]
and [A]
to [D],
[#], [ ]
-
-
ADJUSTMENT