![Kenwood KCH-16 Service Manual Download Page 54](http://html.mh-extra.com/html/kenwood/kch-16/kch-16_service-manual_191017054.webp)
KCH-16
54
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations / Remarks
Test-
equipment
Unit
Terminal
Unit
Parts
Method
• Narrow
3) Adj item: [N SQON]
Adjust: [***]
SSG output
: 12dB SINAD level –3dB
(MOD: 1kHz/±1.5kHz)
SSG
AF VTVM
Oscillo-
scope
Rear
panel
ANT
EXT.SP
Front
panel
[Orange] After input signal
from SSG, press
[Orange] key.
That numeric will be
stored in memory.
After adjusting SQL, check
SQL open/Close.
[Panel test mode]
1) CH-Sig: 1-1
SSG 12dB SINAD or less
: Open
SSG –130dBm (0.07µV)
: Close
2) CH-Sig: 2-1
SSG 12dB SINAD or less
: Open
SSG –130dBm (0.07µV)
: Close
3) CH-Sig: 2-1
SSG 12dB SINAD or less
: Open
SSG –130dBm (0.07µV)
: Close
8. Squelch
(Tight) adjust
• Wide
1) Adj item: [W SQTW]
Adjust: [***]
2) Adj item: [WL SQTW]
→
[WC SQTW]
→
[WH SQTW]
Adjust: [***]
SSG output
: 12dB SINAD level +5dB
(MOD: 1kHz/±3kHz)
After adjusting SQL, check
SQL open/close.
[Panel test mode]
1) CH-Sig: 1-1
SSG 16dB SINAD or more
: Open
SSG 12dB SINAND level –4dB
: Close
2) CH-Sig: 2-1
SSG 16dB SINAD or more
: Open
SSG 12dB SINAD level –4dB
: Close
3) CH-Sig: 3-1
SSG 16dB SINAD or more
: Open
SSG 12dB SINAD level –4dB
: Close
• Narrow
3) Adj item: [N SQTN]
Adjust: [***]
SSG output
: 12dB SINAD level +6.5dB
(MOD: 1kHz/±1.5kHz)
After adjusting SQL, check
SQL open/close.
[Panel test mode]
1) CH-Sig: 1-1
SSG 16dB SINAD or more
: Open
SSG 12dB SINAND level –4dB
: Close
2) CH-Sig: 2-1
SSG 16dB SINAD or more
: Open
SSG 12dB SINAD level –4dB
: Close
3) CH-Sig: 3-1
SSG 16dB SINAD or more
: Open
SSG 12dB SINAD level –4dB
: Close
9. BER (Bit
Error Rate)
check
[Panel test mode]
1) CH-sig: 1-20
SSG output
: –117dBm (0.32µV)
(C4FM)
(1011Hz Tone Test Pattern)
Digital ra-
dio tester
Check
5% or less