7
INSTALLATION REQUIREMENTS
KEY DIMENSIONS AND SPECIFICATIONS
CHOOSE THE PROPER LOCATION
CLEARANCES
FLOORING
WARNING
• Washer is heavy. Two or more people are required
when moving and unpacking the washer.
Failure
to do so may result in damage to property or serious
bodily harm.
• Store and install the washer where it will not be
exposed to temperatures below freezing or exposed
to outdoor weather conditions.
Failure to follow this
warning can cause serious injury, fire, electric shock,
or death.
• Properly ground washer to conform with all electric
governing codes and ordinances (refer to page 5).
Failure to follow this warning can cause serious injury,
fire, electric shock, or death.
• To reduce the risk of electric shock, do not install the
washer in humid spaces.
Failure to follow this warning
can cause serious injury, fire, electric shock, or death.
•
To ensure proper air flow, do not block the large
opening on the bottom of the washer with carpeting
or other materials.
•
Keep the area underneath and around your
appliances free of combustible materials such as lint,
paper, rages, chemicals, etc.
• Do not remove ground prong. Do not use an adapter
or extension cord. Plug into a grounded 3-prong
outlet.
Failure to follow this warning can cause serious
injury, fire, electric shock, or death.
Power Outlet
• The power outlet must be within 60 in. (1.5 m) of either
side of the washer.
• The appliance and outlet must be positioned so that
the plug is easily accessible.
• Do not overload the outlet with more than
one appliance.
• The outlet must be grounded in accordance with
current wiring electric codes and regulations.
• Time-delay fuse or circuit breaker is recommended.
NOTE:
It is the personal responsibility and obligation of
the product owner to have a proper outlet installed by a
qualified service technician.
To ensure sufficient clearance for water lines and airflow,
allow minimum clearances of at least 1 in. (2.5 cm) at the
sides and 4 in. (10 cm) behind the unit. Be sure to allow
for wall, door, or floor moldings that may increase the
required clearances.
NOTE:
The washer must be installed on firm flooring to
minimize vibration during the spin cycle. Concrete
flooring is best, but a wood floor is sufficient, provided
it is built to FHA standards. The washer should not be
installed on rugs or exposed to weather.
• To minimize noise and vibration, the washer MUST be
installed on a solidly constructed floor. See the NOTE
to your right.
• Allowable slope under the entire washer is a maximum
1 in. difference from side to side or from front to back.
• Installing on carpeting and soft tile surfaces is
not recommended.
• Never install the washer on a platform or weakly
supported structure.
Description
Top-Loading Washer
Rated Voltage/Frequency
120VAC, 60Hz
Dimensions
27” (W) X 28 3/8” (D) X 45 3/8” (H), 55 3/4” (H with lid open)
68.6 cm (W) X 72.1 cm (D) X 115.3 cm (H), 141.7 cm (H with lid open)
Net Weight
145.5 lbs. (66 kg)
Minimum vertical space from floor to overhead
shelves, cabinets, ceilings, etc., is 56 in.