Electrical installation
INTORQ | BA 14.0222 | 06/2020
23
6
Electrical installation
Important notes
DANGER
There is a risk of injury by electrical shock!
¾
The electrical connections may only be made by trained electricians!
¾
Make sure that you switch off the electricity before working on the connections! There
is a risk of unintended start-ups or electric shock.
NOTICE
Make sure that the supply voltage matches the voltage specification on the name plate.
6.1
Electrical connection
Switching suggestions
U
N
U = 24V
DC
+24V
GND
14.198.00.xx
Fig. 10:
Switching suggestion for the BFK518
Brake connection line
NOTICE
The wire strands must be routed securely, without kinks, and protected from moving parts.
Use of a glass-fiber-reinforced protective hose is recommended.