Mechanical installation
INTORQ | BA 14.0222 | 06/2020
20
5.5
Brake mounting
Notice
Depending on the particular design, the sequence of assembly steps may vary.
A
B
C
D
Fig. 6:
Mounting the brake
A
Brake BFK518
B
Motor shaft
C
End shield of hub
D
Motor housing (example)
1. Push the brake along with the internal rotor toothing onto the completely cooled hub.
NOTICE
When routing the connecting wire leads, make sure that there is no contact between these
leads and moving parts such as the rotor or armature plate.
Notice
Mount the connecting lead according to the current motor housing being used. Two mounting
options are shown in the illustration:
¾
Mounting the connecting lead in the direction of insertion
¾
Mounting the connecting lead against the insertion direction (This saves space! Refer to
the magnified image.)
2. Route and contact the connecting lead. Pay attention to the following: The connecting lead must be
routed in such a way that the permissible bending radii are observed! Damage caused by sharp edges
must be avoided.