X5 FastMig
Operating manual - EN
Dirty and/or poor quality weld
Check that the shielding gas has not run out.
Check that the shielding gas flow is unobstructed.
Check that the gas type is correct for the application.
Check the polarity of the gun/electrode.
Check that the welding procedure is correct for the application.
Varying welding performance
Check that the wire feed mechanism is adjusted properly.
Blow compressed air through the wire liner to check that it is not
blocked.
Check that the wire liner is correct for the selected wire size and
type.
Check the welding gun contact tip's size, type and wear.
Check that the welding gun is not overheating.
Check that the earth return clamp is properly attached to a clean
surface of the workpiece.
High spatter volume
Check the welding parameter values and welding procedure.
Check the gas type and flow.
Check the polarity of the gun/electrode.
Check that the filler wire is correct for the current application.
"Error codes" on the next page
© Kemppi
94
1920960 / 2039
Summary of Contents for X5 FastMig Manual 400
Page 1: ...X5 FastMig Operating manual EN X5 FastMig Kemppi 2 1920960 2039...
Page 29: ...X5 FastMig Operating manual EN Kemppi 30 1920960 2039...
Page 36: ...X5 FastMig Operating manual EN 1 2 Kemppi 37 1920960 2039...
Page 108: ...X5 FastMig K ytt ohje FI X5 FastMig Kemppi 109 1920960 2039...
Page 136: ...X5 FastMig K ytt ohje FI Kemppi 137 1920960 2039...
Page 143: ...X5 FastMig K ytt ohje FI 1 2 Kemppi 144 1920960 2039...