X5 FastMig
Operating manual - EN
Upslope
ON/OFF
Upslope is a welding function that determ-
ines the time, during which the welding
current gradually increases to the desired
welding current level at the start of the
weld. The upslope start level and time are
preset by the user.
Upslope start level
ON: 10 ... 100 %, step 1
Default = 50
Upslope time
ON: 0.1 ... 5 s, step 0.1
Default = 0.10
Hot start
ON/OFF
Welding function that uses higher or lower
wire feed speed and welding current at the
start of the weld. After the Hot start period
the current changes to normal welding cur-
rent level. This facilitates the start of the
weld especially with aluminum materials.
The Hot start level and time (only in 2T trig-
ger mode) are preset by the user.
Hot start level
ON: -50 ... +200 %, step 1
Default = 40
Hot start duration
ON: 0.0 ... 9.9 s, step 0.1
Default = 1.2 s
Crater fill
ON/OFF
When welding with high power, a crater is
usually formed at the end of the weld. The
Crater fill function decreases the welding
power / wire feed speed at the end of the
welding job so that the crater can be filled
using a lower power level. With 1-MIG pro-
cess, Crater fill start level, duration and end
level are preset by the user.
- Crater fill start level
10 ... 150 %, step 1
Default = 100
- Crater fill duration
0.0 ... 10.0 s, step 0.1
Default = 1.0 s
- Crater fill end level
10 ... 150 %, step 1
Default = 30
Current
10 ... machine size A, step 1
Default = 50 A
Welding current adjustment. With WisePen-
e only.
Fine tuning
Example: -10.0 ... +10.0 V *
Step 0.1 V
Fine tuning of the welding voltage.
* The voltage range for fine tuning is
defined by the active welding program.
Wise feature
None, WiseFusion, WisePene,
WiseSteel
When selected, a list of available Wise fea-
tures is opened for selection.
Wire feed speed limit min
Min/Max = 0.5 ... 25 m/min, step 0.1
Default = 0.5 m/min
Minimum and maximum limits for the wire
feed speed adjustment.
Wire feed speed limit max
Min/Max = 0.5 ... 25 m/min, step 0.1
Default = 25 m/min
TIG welding parameters
The parameters listed here are available for adjustment with the TIG process.
Parameter
Parameter value
Description
Trigger logic
2T, 4T
Welding guns can have several alternative
trigger operation modes (trigger logics).
Most common are 2T and 4T. In 2T mode
you hold the trigger down while welding.
In 4T mode you press and release the trig-
ger to start or to stop welding.
Dynamics
-10.0 ... +10.0, step 0.2
Default = 0
Controls the short circuit behavior of the
arc. The lower the value the softer the arc,
the higher the value the rougher the arc.
© Kemppi
75
1920960 / 2039
Summary of Contents for X5 FastMig Manual 400
Page 1: ...X5 FastMig Operating manual EN X5 FastMig Kemppi 2 1920960 2039...
Page 29: ...X5 FastMig Operating manual EN Kemppi 30 1920960 2039...
Page 36: ...X5 FastMig Operating manual EN 1 2 Kemppi 37 1920960 2039...
Page 108: ...X5 FastMig K ytt ohje FI X5 FastMig Kemppi 109 1920960 2039...
Page 136: ...X5 FastMig K ytt ohje FI Kemppi 137 1920960 2039...
Page 143: ...X5 FastMig K ytt ohje FI 1 2 Kemppi 144 1920960 2039...