X5 FastMig
Operating manual - EN
Post gas
0.0 ... 9.9 s, step 0.1
0.0 = OFF
Welding function that continues the shield-
ing gas flow after the arc has extinguished.
This ensures that the hot weld does not
come into contact with air after the arc is
extinguished, protecting the weld and also
the electrode. Used for all metals. Especially
stainless steel and titanium require longer
post gas times.
Current
10 ... machine size A, step 1
Default = 50 A
Welding current adjustment.
MMA welding parameters
The parameters listed here are available for adjustment with the MMA process.
Parameter
Parameter value
Description
Dynamics
-10.0 ... +10.0, step 0.2
Default = 0
Controls the short circuit behavior of the
arc. The lower the value the softer the arc,
the higher the value the rougher the arc.
Hot start level (MMA)
-30 ... +30
Default = 0
Welding function that uses higher or lower
wire feed speed and welding current at the
start of the weld. After the Hot start period
the current changes to normal welding cur-
rent level. This facilitates the start of the
weld especially with aluminum materials. In
MMA the Hot start level is preset by the
user.
Current
10 ... machine size A, step 1
Default = 50 A
Welding current adjustment.
Gouging parameters
The parameters listed here are available for adjustment with the gouging process.
Parameter
Parameter value
Description
Current
10 ... machine size A, step 1
Default = 50 A
Current adjustment.
3.3.5 Auto control panel: Info view
The Info view shows information on the device usage. Through this view it is also possible to access the error logs,
list of installed welding programs, additional operating information and device info, such as the software version
and equipment serial numbers.
© Kemppi
76
1920960 / 2039
Summary of Contents for X5 FastMig Manual 400
Page 1: ...X5 FastMig Operating manual EN X5 FastMig Kemppi 2 1920960 2039...
Page 29: ...X5 FastMig Operating manual EN Kemppi 30 1920960 2039...
Page 36: ...X5 FastMig Operating manual EN 1 2 Kemppi 37 1920960 2039...
Page 108: ...X5 FastMig K ytt ohje FI X5 FastMig Kemppi 109 1920960 2039...
Page 136: ...X5 FastMig K ytt ohje FI Kemppi 137 1920960 2039...
Page 143: ...X5 FastMig K ytt ohje FI 1 2 Kemppi 144 1920960 2039...