X5 FastMig
Operating manual - EN
Water cooler
OFF/Auto/ON
Default = OFF
When ON is selected, the coolant is cir-
culated continually, and when Auto is
selected, the coolant is circulated only dur-
ing welding. The Auto mode is available
only with welding guns supporting the
automatic detection.
Weld data duration
0 ... 30 s, step 1
0 = OFF
Default = 5 s
This defines if and how long the weld data
summary is shown after each weld.
Date
Current date
Time
Current time
Language
Available languages
Factory reset
Reset/Cancel
Default = Cancel
Safe wire inch
(with MIG only)
OFF/ON
When ON, and the arc doesn't ignite, the
filler wire is fed 5 cm When OFF, 5 m of filler
wire is fed.
Cable calibration
(with MIG only)
Start/Cancel
The date and time and the calibration
information of the previous calibration is
also shown.
Refer to
"Calibrating welding cable" on
for cable calibration.
VRD
(with MMA and gouging only)
OFF/12V/24V
Default = OFF
Voltage reduction device (VRD) reduces
the open-circuit voltage to maintain below
a certain voltage value.
3.3.8 Auto control panel: Applying welding programs
Use the welding program that is in accordance with your welding setup (e.g. welding wire and gas properties).
The use of additional welding programs and Wise features is possible with the X5 FastMig Synergic equipment in MIG
operation mode.
1.
Go to the Memory channels view. (Refer to "Auto control panel: Memory channels" on page 70 for more inform-
ation.)
2.
Enter the actions menu.
3.
Select
Create channel
.
>> A filter view opens.
© Kemppi
79
1920960 / 2039
Summary of Contents for X5 FastMig Manual 400
Page 1: ...X5 FastMig Operating manual EN X5 FastMig Kemppi 2 1920960 2039...
Page 29: ...X5 FastMig Operating manual EN Kemppi 30 1920960 2039...
Page 36: ...X5 FastMig Operating manual EN 1 2 Kemppi 37 1920960 2039...
Page 108: ...X5 FastMig K ytt ohje FI X5 FastMig Kemppi 109 1920960 2039...
Page 136: ...X5 FastMig K ytt ohje FI Kemppi 137 1920960 2039...
Page 143: ...X5 FastMig K ytt ohje FI 1 2 Kemppi 144 1920960 2039...