X5 FastMig
Operating manual - EN
40
VRD error
Open circuit voltage exceeds the VRD limit.
Restart the power source. If problem persists, contact
Kemppi service.
42
High current
in wire feeder
motor
There may be too much pressure in the wire
feed rolls or dirt in the wire line.
Adjust the feed roll pressure. Clean the wire line. Change
worn parts in the welding gun.
43
Overcurrent in
wire feeder
motor
There may be too much pressure in the wire
feed rolls or dirt in the wire line.
Adjust the feed roll pressure. Clean the wire line. Change
worn parts in the welding gun.
44
Wire speed
measurement
is missing
Faulty sensor or wiring in wire feeder.
Restart the welding system. If problem persists, contact
Kemppi service.
50
Welding pro-
gram error
Required welding program is not installed.
Contact Kemppi service for installing welding programs.
62
Power source
not found
No power source is connected to the wire
feeder, or connection is faulty.
Check the control cable and its connectors.
81
Welding pro-
gram data
missing
Welding program data has been lost.
Restart the power source. If problem persists, contact
Kemppi service.
244
Internal
memory fail-
ure
Initialization failed (%sub:%device).
Restart welding system. If problem persists, contact
Kemppi service.
250
Internal
memory fail-
ure
Memory communication failed (%sub:%device).
Restart welding system. If problem persists, contact
Kemppi service.
© Kemppi
96
1920960 / 2039
Summary of Contents for X5 FastMig Manual 400
Page 1: ...X5 FastMig Operating manual EN X5 FastMig Kemppi 2 1920960 2039...
Page 29: ...X5 FastMig Operating manual EN Kemppi 30 1920960 2039...
Page 36: ...X5 FastMig Operating manual EN 1 2 Kemppi 37 1920960 2039...
Page 108: ...X5 FastMig K ytt ohje FI X5 FastMig Kemppi 109 1920960 2039...
Page 136: ...X5 FastMig K ytt ohje FI Kemppi 137 1920960 2039...
Page 143: ...X5 FastMig K ytt ohje FI 1 2 Kemppi 144 1920960 2039...