Manual Operation
63
4.5.7.3
ANALOG OUT menu
In the submenu “ANALOG OUT” the 4 – 20mA outputs can be configured.
Each analog output can show one of the following 4 parameters:
FLOW:
The output current is proportional to the actual flow.
DENSITY:
The output current is proportional to the actual density.
TEMPERATURE:
The output current is proportional to the actual temperature.
BATCH COUNT:
The output current is proportional to the actual batch value.
This mode is only possible, if the control input is configured as “RESET BATCH”
The value for 4mA as well as the value for 20mA can be freely selected. Thus it is possible to zoom in (e.g.
temperatures from 20°C to 30°C) or to show negative values as well (e.g. flow from -10kg/min to +20kg/min).
IN/OUTPUTS MENU
ANALOG OUT
UP DOWN EXIT
P
ANALOGQ OUT MENU
CURRENT 1
UP DOWN EXIT
Use the keys “UP” and “DOWN” to select the desired output channel and confirm with “P” or skip with “E”.
The display shows
SELECT OUTPUT MODE
FLOW
UP DOWN EXIT
Use the keys “UP” and “DOWN” to select the desired output value and confirm with “P” or skip with “E”.
The display shows
VALUE AT 4mA
0.50000
G/S
RIGHT UP EXIT
The indicated engineering unit depends on the selected output value and the display setup.
Use the keys “RIGHT” and “UP” to select the desired value for 4 mA and confirm with “P” or skip with “EXIT”.
The display shows
VALUE AT 20mA
5.00000
G/S
RIGHT UP EXIT
Use the keys “RIGHT” and “UP” to select the desired value for 20 mA and confirm with “P” or skip with “EXIT”.
The display returns to the IN/OUTPUT menu..
Summary of Contents for TRICOR TCE80 -E Series
Page 1: ...Certified according to DIN ISO 9001 Manual TRICOR Coriolis Mass Flow Meter ...
Page 2: ...SW Version Main V2 0x Display V2 0x Manual Revision 2 1 ...
Page 93: ...Listings 93 Fig 26 Dimensions TCE8000 E except A Fig 27 Dimensions TCE8000 E A ...
Page 98: ...Contact Copyright KEM Subject to change without notice ES Rev 002 23 01 2012 ...