![KCM 70Z7 Operation & Maintenance Manual Download Page 292](http://html2.mh-extra.com/html/kcm/70z7/70z7_operation-and-maintenance-manual_5095087292.webp)
MAINTENANCE
7-51
1
2
3
4
5
Replace Air Breather Element
--- every 2000 hours
WARNING: Hydraulic oil becomes hot during
operation. Severe burns may result if skin comes in
contact with hot hydraulic oil. Wait for the oil to cool
before starting any maintenance work.
Replacement Procedures
1. Park the machine following the same procedures as
described on page 7-7 for preparation of inspection/
maintenance work.
2. Before replacing the filter element, be sure to relieve the
air pressure from the hydraulic oil tank by pressing air
bleed valve (1).
3. Rotate cover (3) clockwise approx. 1/4 turns. Remove cap
(2) by rotating it counterclockwise.
4. Rotate cover (3) counterclockwise and remove it.
Remove element (4).
5. Install new element (4). Tighten cover (3) clockwise.
After cover (3) come in contact with the inside element,
tighten the cover 1/4 turn further.
6. Manually tighten cap (2) clockwise to the end. Hold cap
(2) in position by hand to prevent the cap from turning.
Tighten cover (3) counterclockwise 5 to 10° securely.
7. Take care not to allow water or dust to enter the
clearance (air discharge port) between cover (3) and
body (5).
8. Replace the element at the recommended regular
intervals to keep the hydraulic oil clean and to extend
the service life of the hydraulic equipment.
M4GB-07-044
M4GB-07-166
Summary of Contents for 70Z7
Page 2: ...93108 00691 April 2015...
Page 5: ......
Page 11: ...MACHINE NUMBERS 2 MEMO...
Page 51: ...SAFETY LABELS S 40 6 10 4 1 3 9 6 5 SS 3461...
Page 171: ...OPERATOR S STATION 1 110 MEMO...
Page 173: ...BREAK IN 2 2 MEMO...
Page 187: ...OPERATING THE ENGINE 3 14 MEMO...
Page 231: ...OPERATING THE MACHINE 5 24 MEMO...
Page 359: ...MAINTENANCE 7 118 MEMO...
Page 363: ...MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS 9 4 MEMO...
Page 367: ...STORAGE 10 4 MEMO...