![KCM 70Z7 Operation & Maintenance Manual Download Page 272](http://html2.mh-extra.com/html/kcm/70z7/70z7_operation-and-maintenance-manual_5095087272.webp)
MAINTENANCE
7-31
Replace Crankcase Air Breather Element
--- Every 2000 hours
WARNING: Be sure to wear safety glasses when using
compressed air (0.2 MPa (2 kgf/cm
2
, 30 PSI)).
1. Park the machine following the same procedure as
described on page 7-7 for preparation of inspection/
maintenance work.
2. Remove oil filler cap (1).
3. Remove bolts (2) from crankcase air breather cover (3).
NOTE: Make a note of bolt (2) position for reference at
assembling work.
4. Remove crankcase air breather cover (3).
5. Remove air breather element (4) from rocker lever cover
(5).
Do not remove gasket (6) from the rocker lever cover.
IMPORTANT: If gasket (6) sticks out from the rocker lever
cover (5) groove, install new gasket.
6. If any damage is found on the gasket, remove it by
pulling gasket tab (7).
CAUTION: Be sure to wear safety glasses and gloves
when using detergent for cleaning.
MNEC-07-107
MNEC-07-108
MNEC-07-109
MNEC-07-110
1
2
4
5
3
6
6
6
7
Summary of Contents for 70Z7
Page 2: ...93108 00691 April 2015...
Page 5: ......
Page 11: ...MACHINE NUMBERS 2 MEMO...
Page 51: ...SAFETY LABELS S 40 6 10 4 1 3 9 6 5 SS 3461...
Page 171: ...OPERATOR S STATION 1 110 MEMO...
Page 173: ...BREAK IN 2 2 MEMO...
Page 187: ...OPERATING THE ENGINE 3 14 MEMO...
Page 231: ...OPERATING THE MACHINE 5 24 MEMO...
Page 359: ...MAINTENANCE 7 118 MEMO...
Page 363: ...MAINTENANCE UNDER SPECIAL ENVIRONMENTAL CONDITIONS 9 4 MEMO...
Page 367: ...STORAGE 10 4 MEMO...