39
Operation and Service KBL 5600
Connecting the external timer
CONNECTING VIA AMP PLUG (DEFAULT)
Connect the external timer (e.g. coin box, studio
control) according to the instructions supplied with
the timer. The connection is made via the socket
for an AMP plug on the back side of the device.
The following diagram shows the wiring of the timer
connection.
timer
L1
start
remote start
11
13
1
2
socket for AMP plug
AMP plug
USING T-MAX
STEP
PROCEDURE
Fig.
1
Remove the front cover and pull out the
electronics carriage completely. The console
with the spacer supports for the board can be
found inside at the right side of the electronics
carriage.
2
Attach the board to the spacer supports.
Connect the edge connector and the white
plug to the board.
3
Remove X.9 and connect X.9A (located at the
right side of the electronics carriage).
4
Connect the RJ22 cable to the board and guide
it together with the power or RCA jack cable
through the feedthrough in the back.
Connecting the channel selection
The following diagrams show the wiring of the channel
selection on the audio equipment’s side, for pulse
coding and for BCD coding.
Wiring on the audio system of the studio
PE
1
2
3
4
5
V
olume +
V
olume -
ch. selection -
ch. sel
Control volt
age
puls-coding
Wiring on the audio system of the studio
PE
1
2
3
4
5
Control volt
age
BCD-coding
Channel selection
Channel selection
CHANNEL
BCD CODING
1
0
0
2
1
0
3
0
1
4
1
1
Summary of Contents for megaSun 5600
Page 1: ...Operating and Maintenance KBL 5600 BA_5600_US_L 0707...
Page 56: ......