5. Maintenance of the sun bed
Preparatory works
Before you open the apparatus, switch off the fuses to discon-
nect it from the mains supply!
Do not operate the tanning unit without the front panels, without
acrylic panes or with the base section opened, because other-
wise the tanner areas will become overheated. This will destroy
the "lter panes!
As far as CPI-equipped units are concerned, the electronic
switchboxes located under the bed are also exposed to the dan-
ger of overheating.
5.1 Cleaning and care
Plastic parts
Chromed parts
The bigger plastic parts are made of solid, high-quality ABS
material.
The surfaces and the acrylic glass must not be cleaned with
concentrated disinfectants or solvents or other liquids that
contain alcohol! The manufacturer cannot be held liable for
any damages caused by chemically active agents such as
inappropriate cleaning agents. To clean the varnished and plastic
surfaces use a damp soapy cloth.
It must be avoided at any rate that cleaning #uid runs into the
apparatus.
Clean only with a damp (not wet) washleather and a plexiglass
cleaner (antistatic). The cleaning agent must be applied onto the
cleaning cloth and not directly onto the chromed parts.
Acrylic panes
For a harmless cleaning of the acrylic panes use the special
cleaning and disinfectant fluid „megaClean “ (to be obtained
from KBL) which has to be diluted in water at a ratio of 1:13.
Fixing the canopy
The canopy can be fixed in the upper position, to perform
service and maintenance works.
To do so, turn the lever of the left hand side of the tanning
system to the left. Lift the canopy to the upper position and it
will remain in this position. To release the canopy again, turn the
lever to the right.
After removing the screws on the left and on the right, the bed
pane can be fastened to the canopy.
Illustr. 5-1 Fixing the canopy