34
Installation site
In dry rooms with sufficient air supply and ventilation
Relative humidity
≤70 %
Ambient temperature
≤ 86°F (30°C)
ATTENTION!
The unit must not be operated if the coin/timer system or
the internal control system of the maximum tanning time
is defective or if a filter is broken or missing.
Outlet
At the left-hand rear side of the unit
Disposal
Connection to sewage system or tank (capacity ≥5l)
Quantity
Depending on local conditions and air humidity
Note
For the purpose of pumping the water off, the power
supply must not be disconnected after the tanning
session
Length x width x height
~92.91” L x ~49.60” W x ~55.12” H when closed
~92.91” L x ~49.60” W x ~70.87” H when opened
Central exhaust air duct
Diameter
Height (top edge)
~11.81”
~62.99”
Exhaust air hose
Ø ~11.81”
Weight (with air-
conditioning unit)
~1477.1 lbs
Power supply
3-phase: 3x 220 V / ~ / 60 Hz
2-phase: 2x 220 V / ~ / 60 Hz
Fuses
3-phase: 3x 40 A (for Canada with ground fault circuit interrupter)
2-phase: 2x 55 A (for Canada with ground fault circuit interrupter)
Wires and diameter 3-phase: 4x AWG8
2-phase: 3x AWG8
Internal plug: 220 V For PC, lamp etc., NOT for high loads.
Electrical connection
Operation and Service KBL 5600
6. Technical data
6.1 Data which all apparatuses have in common
Ambient conditions
Condensate
Dimensions of KBL 5600