20
Step
Procedure
Reference
1
Dismantle the canopy pane, base pane and lateral pane.
Section 5.2
2
Remove the tube covers in the facial area.
Section 3.3.
3
For apparatuses equipped with burners: You will have to
dismantle the filter panes as well, if you want to replace
the burner.
Section 5.3,
5.5
4
Remove the covers of the shoulder tanners.
Section 5.6
All
tanning
units
All units with
burners
Inductive units
CPI units
Shoulder
tanner
Burner
Tubes
and
Starters
with facial
tanner mode
without facial
tanner mode
Eco
Power
Eco
Power
500 hrs.
500-600 hrs.
500-600 hrs.
800 hrs.
500 hrs.
1000 hrs. 800 hrs.
Carry out a reset!
Operation and Service KBL 5600
5.4 Tubes, facial and shoulder tanners
Dismantling
Carry out the following procedure to clean or replace tubes or
face and shoulder tanners:
Cleaning intervals
Unit lighting
To make sure that the tanning effect is maintained, we
recommend you to clean the tubes and UV radiators with warm
water and a chamois after approx. every 200 hours of use. Do
not use any aggressive or alcoholic cleaning agents.
The coloured fi lter (Sec. 5.7 Unit lighting) has to replaced at the
latest when replacing the tanning tubes.
Replacement
intervals
Only replace tubes, face tanners, shoulder tanners and starters
with those of the same type!
When installing the tubes, make sure that the inscription is
visible, i.e. the re#ector must be at the back.
For units equipped with CPI technology, it is essential to carry
out a reset after each tube replacement! (see Section 8.2.2)
For units equipped with inductive technology also install new
starters when replacing the tubes!
After each change of tubes, do not forget to reset the counter of
the service hours of the tubes. (see Section 8.3.)