![Kauai Labs navX2-MXP User Manual Download Page 37](http://html1.mh-extra.com/html/kauai-labs/navx2-mxp/navx2-mxp_user-manual_3634856037.webp)
Software
navXUI
Gyro Calibration in Progress Indicator
The Gyro Calibration in Progress Indicator is displayed during initial gyroscope calibration, which occurs
immediately after power is applied to the navX-sensor. If the gyroscope calibration does not complete,
the navX-sensor yaw accuracy will be adversely impacted. For more information on Gyro Calibration,
please see the
Gyro/Accelerometer Calibration
Motion Indicators
The navX-sensor provides dynamic motion indicators: (a) the “Moving” indicator and (b) the “Rotating”
indicator.
The Moving indicator is present whenever the current Gravity-corrected Linear Acceleration exceeds the
“Motion Threshold”.
The Rotating indicator is present whenever the change in yaw value within the last second exceeds the
“Rotating Threshold”. Note that the navX-sensor Gyroscope Calibration only occurs when the navX-
sensor is not Rotating for a few seconds.
Gravity-corrected Linear Acceleration (G)
34