two inches from combustibles. Vents passing through 
enclosed spaces and vents exposed to the weather 
should also be the double-wall type. Sometimes vents 
have to be built of such great length that they come 
apart at their joints under their own weight. These 
should be screwed together at the joints with sheet 
metal screws, usually three per joint. If the inspector 
indicates that the vent is too close to combustibles, it 
may be necessary to chisel away some of the com-
bustible or route the vent pipe around the combustible. 
The cross-sectional area of any fl ue shall not be less 
that the cross-sectional area of the fl ue vent connec-
tion outlet of machine.

The pressure washer includes a collar that will mate 
with standard HVAC ducting.  The user will be respon-
sible for installation of an exhaust stack.  The exhaust 
stack should include a Draft Diverter/Inducer, Damper, 
Sampling Port and Rain Cap.   An adapter can be 
installed between the collar and stack to adjust the 
diameter from 10” to 8” or 12” to 10”.

Size the stack according to the following (see also 
applicable local and national standards regarding 
installation of gas-fi red appliances):

• 

3.5 to 4.4 gpm 

10” Collar 

 8” Stack

• 

4.5 to 5.5 gpm 

10” Collar 

10” Stack

• 

6.3 gpm 

 

12” Collar 

10” Stack

• 

8 – 10 gpm   

12” Collar 

12” Stack

(Figure 4)

Draft Diverter/Hood:

  The draft required to vent 

combustion gases is created by the heat inside the 
pressure washer coil.  A draft diverter helps improve 
draft into the stack without pulling more air through the 

combustion box and decreasing combustion effi ciency.  
The draft diverter can also help prevent back drafting 
that can inhibit combustion.  The draft diverter should 
be installed a minimum of 36” above the fl ue collar.  

See Figure 4.

Power Vent (Draft Inducer):  

If this machine is going 

to be installed on a 90° or extended exhaust vent run 
length which may restrict air fl ow it is recommended 
that a contractor install a power vent. When a contrac-
tor has found it impossible to vent straight through the 
roof  power venting is recommended to help eliminate 
exhaust restriction of this natural draft machine. This 
draft inducer (power vent) must be installed by a li-
censed contractor who can calculate size, operation 
connections and associated dampeners. Since we 
are a manufacturer and not a licensed contractor and 
as such we are unable to make recommendations for 
suitable make and model of power vents and compli-
ance with local building codes.

Damper:

  An exhaust stack can reduce thermal ef-

fi ciency by drawing in too much combustion air.  This 
can be controlled by adding a damper just below the 
draft diverter. 8.753-473.0 - 8" Damper, 8.753-474.0  
-10" Damper, 8.753-418.0 - 12" Damper.

NOTE:

  Closing the damper can create high levels of 

CO in the exhaust.  Adjustments to the damper should 
only be performed by a trained technician using a fl ue 
gas analyzer.  If an analyzer is not used the damper 
should be set in the fully open position.

Sampling Port

:  A port for sampling fl ue gases and 

measuring the fl ue gas temperature should be placed 
18” above the fl ue collar.  The port should be covered 
when sampling is not being performed.  The size of 
the port should be only slightly larger than the probe 
for the fl ue gas analyzer.

Rain Cap:

  A rain cap should be installed on top of 

the stack to prevent rain water, leaves and debris from 
entering the stack.  Your installer may also recommend 
specialty caps for high wind areas or cold weather 
zones to help prevent back drafting. 8.717-731.0 - 10" 
Raincap, 8.717-732.0 - 12" Raincap.

Water Source:

The water source for the machine should be sup plied 
by a 5/8" I.D. gar den hose with a city water pressure of 
not less than 30 PSI. If the water supply is in ad e quate, 
or if the garden hose is kinked, the machine will run 
very rough and the burner will not fi re.

Water Connection:

Connect the high pressure hose by pulling the cou pler 
col lar back and then inserting it onto the dis charge 
nip ple. Se cure it by pushing the collar forward.

Attach the wand into the spray gun using tefl on tape 
on the pipe threads to avoid leaks.

INSTALLATION

Illustration showing air openings necessary

to supply air for combustion when installed 

in an enclosed room.

Figure 3: Ventilation

Draft Diverter

Required

  8.717-728.0     8"
  9.801-040.0   10"
  8.717-730.0   12"

Summary of Contents for HDS3.5/20

Page 1: ...DES LUN ETTE S DE SEC URIT E DOIV ENT ETR E POR TEES lorsq ue vous oper ez cet appa reil RISK OF ASP HYX IATI ON Use only in well vent i lated area RIES GO DE ASF IXIA Use el prod ucto en un area de...

Page 2: ...is on it means the overload is tripped Reset overload Pilot Light When the light is on it means there is power to the pilot control If there is no light see troubleshooting guide Voltage When the lig...

Page 3: ...9 30 5 0 23 4 8 30 8 Installation HDS 6 3 32 8 0 32 9 5 30 19 Installation 10 16 Assembly Instructions 17 Operating Instructions 18 Applying Detergent General Washing Techniques 19 Shutting Down Clea...

Page 4: ...ly familiar with the controls 3 Stay alert watch what you are doing 4 Use only your hand to push in or turn the gas control knob Never use a tool If the knob will not push in or turn by hand don t try...

Page 5: ...discharge stream at people or severe injury or death will result WARNING PROTECT FROM FREEZING WARNING Protect machine from freezing 13 To keep machine in best operating conditions it is importantyou...

Page 6: ...WARNING If connection is made to potable water supply a back flow device must be provided 27 Exhaust gases should not be vented into a wall a ceiling or a concealed space of a building A draft diverte...

Page 7: ...DOR ES CAL IFIC ADO S LIRE LE MAN UEL DE L OP ERA TEU R AVA NT UTIL ISAT ION CET APP ARE IL DOIT ETR E UTIL ISE PAR DES OPE RA TEU RS QUA LIFIE S RIS K OF INJU RY PRO TEC TIVE EYE WEA R AND CLO THIN G...

Page 8: ...9 50 Dia Customer Supplied Draft Diverter 24 00 24 87 4 00 High Pressure Out 22mm Screw Connection 48 54 36 68 24 50 24 00 12 00 49 00 Water In 3 4 GHF 21 30 20 61 20 61 Exhaust Out 10 Dia NOTE Draft...

Page 9: ...side Floor Mounting Dimensions 19 50 Dia Customer Supplied Draft Diverter Control Panel 61 00 17 33 34 79 17 36 26 18 3 64 High Pressure Out 22mm Screw Connection 31 77 64 00 26 91 26 91 Water In 3 4...

Page 10: ...s recommended that a partition be made be tween the wash area and machine to prevent direct spray from the spray gun from coming in contact with the machine Excess moisture reaching the power unit or...

Page 11: ...roved by the Uniform Building Code Vents penetrating ceilings or walls should be double wall approved appliance vents and should be one to INSTALLATION LP Gas Liquid petroleum gas or propane LP gas is...

Page 12: ...e roof power venting is recommended to help eliminate exhaust restriction of this natural draft machine This draft inducer power vent must be installed by a li censed contractor who can calculate size...

Page 13: ...fluenced by the heat created inside the coil the design of the coil and flue and the length and diameter of the exhaust stack The table below shows data included in the operator s manual for flue and...

Page 14: ...is 4 2 wc in For an installation at 3500 feet reduce this pressure by 16 by setting the manifold pressure to 4 2 84 3 5 wc in This adjustment should only be made by a properly trained service technici...

Page 15: ...ollow instructions carefully when installing or servicing machine Failure to do so may result in damage to property or personal injury 1 Installation or servicing of gas appliances and controls must o...

Page 16: ...y for the BTU rating of the burner Is incoming gas supply pressure between 6 14 water column inches or 1 2 PSIG Has the proper gas regulator been installed for pressure and volume Have you installed t...

Page 17: ...will result Safety Latch Spray Gun High Pressure Hose 98015080 7 STEP 3 Connect garden hose to the cold water source Cold Water Source Garden Hose 98015080 10 STEP 6 Attach the Power Nozzle to end of...

Page 18: ...rgent Valve STEP 4 To apply detergent open the detergent valve counterclock wise making sure that the deter gent pick up tube is in the detergent solution and not sucking air 98016360 17 NOTE High pre...

Page 19: ...his thermal device prevents internal damage to the pump CLEANING TIPS Pre rinse cleaning surface with fresh water Place detergent suction tube directly into cleaning solu tion and apply to surface For...

Page 20: ...du syst me F Coupez l eau W ARNIN G PRE CAU CION AVE RTIS SEM ENT SK AL E NE BY ORS LEA EL MANUA L OPERA CION ANTES DE USARS E ESTE EQUIPO DEBE SER USADO SOLAM ENTE POR OPERA DORES CALIFIC ADOS LIRE L...

Page 21: ...ugging metering valve Disassemble and clean thoroughly High viscosity of detergent Dilute detergent to specifications Restriction behind float tank screen removed Install restriction Hole in detergent...

Page 22: ...all repair kit when needed Worn packing in pump Install new packing kit Fouled or dirty inlet or discharge valves in pump Clean inlet and discharge valve Worn inlet or discharge valves Replace with va...

Page 23: ...scale 1 Be sure main gas valve gas cock or selector arm is turned on 2 With gas on and system sparking probe terminals PV and 24V GND If pilot gas does not flow with 24 volts at these terminals repla...

Page 24: ...switch on With the pilot burning and the flame on the ignitor sensor rod the main burner should turn on If it does not replace the ignition control unit SHORT CYCLING OF MAIN BURNER MAIN BURNER TURNS...

Page 25: ...ump needs repairing CAUTION When using this procedure to test components keep the spray gun open at all times High Limit Hot Water Thermostat For safety each machine is equipped with a high limit cont...

Page 26: ...installed between pro pane bottle and gas valve Propane Cylinder Capacity An important consideration with propane systems is the capacity of the supply cylinder relative to the needs of the burner The...

Page 27: ...through the coil by whatever means are available for the particular system the water heater is used on To Adjust Pressure Regulator Adjustment of the pressure regulator is not normally necessary since...

Page 28: ...Lbs per Gal Liquid 4 23 4 87 BTU per Cu Ft Vapor 2 563 3 39 BTU per Gal Liquid 91 547 102 032 BTU per Lb Liquid 21 591 21 221 Cu Ft per Lb Liquid 8 607 6 53 Cu Ft per Gal Liquid 36 45 31 8 Octane Numb...

Page 29: ...essure gauge At the lower levels it is expressed in water column inches i e 11 w c i Higher pressures are expressed in terms of the force exerted against a square inch of area for example 125 lbs per...

Page 30: ...e life of your pressure washer Perform maintenance more often under severe conditions MAINTENANCE SCHEDULE Replace Fuel Lines Annually Pump Oil Inspect Daily inspect the oil level Change After first 5...

Page 31: ......

Page 32: ...HDS 9 801 509 0 Printed in U S A...

Reviews: