background image

 9.801-509.0 - C  •  Karcher Operator's Manual

MANU

AL

   

PRESSURE W

ASHER 

 

6

IMPORTANT SAFETY INFORMATION

22. Install optional LP gas regulator assembly, item

 

  9.802-633.0 or obtain a proper size regulator.

23.  Install this machine about 2 feet from wall to 

provide adequate ventilation and servicing space. 
This equipment incorporates parts such as snap 
switches or similar parts that tend to produce arcs 
or sparks. Therefore, when located in a garage, it 
should be in a room or enclosure provided for the 
purpose or should be installed 18" (457mm) or 
more above the fl oor.

WARNING: To reduce the risk of electric shock, 
disconnect all electrical connections and shut-off 
gas valve before servicing.

 24.  Install this machine on non combustible fl ooring.

 25. Do not allow acids, caustic or abrasive fl uids to 

pass through the pump.

 26. Never run pump dry or leave spray gun closed 

longer than 3 minutes.

WARNING: If connection is made to potable water 
supply, a back fl ow device must be provided.

27.   Exhaust gases should not be vented into a wall, a 

ceiling or a concealed space of a building. A draft 
diverter must be installed to prevent down draft 
and to allow cooling of exhaust temperatures. 
Down draft diverters shall be installed in the 

vents and located at a dis-
tance from the pressure wash-
er stack to achieve maximum 
draft of 36" minimum. Exhaust 
g a s e s   t h a t   ex c e e d   4 7 0 ° F 
(243°C) are not suitable for 
connection to Type B gas vents.

Example of Down Draft Diverter for 

Gas Fired Machines

Follow the maintenance instructions 
specifi ed in the manual. 

 ITEM  PART  NO. 

DESCRIPTION 

QTY

 

 

9.802-633.0 

Regulator, LP Assembly 

1

 

9.802-019.0 

Nipple, 3/4" x 2", Black 

1

 

8.717-747.0 

Regulator, R622CFF for 

 

 

 

R932/28 & R932462 

1

 

8.717-746.0 

Regulator, Hi Pressure, 

    

R321H22 

 

1

 

8.711-855.0 

Hose, 1/2" x 19", Propane 

1

 

8.717-782.0 

Fitting, Pigtail, Fisher, M318    

 

 

 

(Included when ordering part    

    

8.717-746.0) 

1

98015100-48

To

 Pr

opane

Bottle

To

 Pressure 

Washer

Gas Inlet

1

3

5

2

4

Optional 

Regulator Kit

9.802-633.0

Summary of Contents for HDS3.5/20

Page 1: ...DES LUN ETTE S DE SEC URIT E DOIV ENT ETR E POR TEES lorsq ue vous oper ez cet appa reil RISK OF ASP HYX IATI ON Use only in well vent i lated area RIES GO DE ASF IXIA Use el prod ucto en un area de...

Page 2: ...is on it means the overload is tripped Reset overload Pilot Light When the light is on it means there is power to the pilot control If there is no light see troubleshooting guide Voltage When the lig...

Page 3: ...9 30 5 0 23 4 8 30 8 Installation HDS 6 3 32 8 0 32 9 5 30 19 Installation 10 16 Assembly Instructions 17 Operating Instructions 18 Applying Detergent General Washing Techniques 19 Shutting Down Clea...

Page 4: ...ly familiar with the controls 3 Stay alert watch what you are doing 4 Use only your hand to push in or turn the gas control knob Never use a tool If the knob will not push in or turn by hand don t try...

Page 5: ...discharge stream at people or severe injury or death will result WARNING PROTECT FROM FREEZING WARNING Protect machine from freezing 13 To keep machine in best operating conditions it is importantyou...

Page 6: ...WARNING If connection is made to potable water supply a back flow device must be provided 27 Exhaust gases should not be vented into a wall a ceiling or a concealed space of a building A draft diverte...

Page 7: ...DOR ES CAL IFIC ADO S LIRE LE MAN UEL DE L OP ERA TEU R AVA NT UTIL ISAT ION CET APP ARE IL DOIT ETR E UTIL ISE PAR DES OPE RA TEU RS QUA LIFIE S RIS K OF INJU RY PRO TEC TIVE EYE WEA R AND CLO THIN G...

Page 8: ...9 50 Dia Customer Supplied Draft Diverter 24 00 24 87 4 00 High Pressure Out 22mm Screw Connection 48 54 36 68 24 50 24 00 12 00 49 00 Water In 3 4 GHF 21 30 20 61 20 61 Exhaust Out 10 Dia NOTE Draft...

Page 9: ...side Floor Mounting Dimensions 19 50 Dia Customer Supplied Draft Diverter Control Panel 61 00 17 33 34 79 17 36 26 18 3 64 High Pressure Out 22mm Screw Connection 31 77 64 00 26 91 26 91 Water In 3 4...

Page 10: ...s recommended that a partition be made be tween the wash area and machine to prevent direct spray from the spray gun from coming in contact with the machine Excess moisture reaching the power unit or...

Page 11: ...roved by the Uniform Building Code Vents penetrating ceilings or walls should be double wall approved appliance vents and should be one to INSTALLATION LP Gas Liquid petroleum gas or propane LP gas is...

Page 12: ...e roof power venting is recommended to help eliminate exhaust restriction of this natural draft machine This draft inducer power vent must be installed by a li censed contractor who can calculate size...

Page 13: ...fluenced by the heat created inside the coil the design of the coil and flue and the length and diameter of the exhaust stack The table below shows data included in the operator s manual for flue and...

Page 14: ...is 4 2 wc in For an installation at 3500 feet reduce this pressure by 16 by setting the manifold pressure to 4 2 84 3 5 wc in This adjustment should only be made by a properly trained service technici...

Page 15: ...ollow instructions carefully when installing or servicing machine Failure to do so may result in damage to property or personal injury 1 Installation or servicing of gas appliances and controls must o...

Page 16: ...y for the BTU rating of the burner Is incoming gas supply pressure between 6 14 water column inches or 1 2 PSIG Has the proper gas regulator been installed for pressure and volume Have you installed t...

Page 17: ...will result Safety Latch Spray Gun High Pressure Hose 98015080 7 STEP 3 Connect garden hose to the cold water source Cold Water Source Garden Hose 98015080 10 STEP 6 Attach the Power Nozzle to end of...

Page 18: ...rgent Valve STEP 4 To apply detergent open the detergent valve counterclock wise making sure that the deter gent pick up tube is in the detergent solution and not sucking air 98016360 17 NOTE High pre...

Page 19: ...his thermal device prevents internal damage to the pump CLEANING TIPS Pre rinse cleaning surface with fresh water Place detergent suction tube directly into cleaning solu tion and apply to surface For...

Page 20: ...du syst me F Coupez l eau W ARNIN G PRE CAU CION AVE RTIS SEM ENT SK AL E NE BY ORS LEA EL MANUA L OPERA CION ANTES DE USARS E ESTE EQUIPO DEBE SER USADO SOLAM ENTE POR OPERA DORES CALIFIC ADOS LIRE L...

Page 21: ...ugging metering valve Disassemble and clean thoroughly High viscosity of detergent Dilute detergent to specifications Restriction behind float tank screen removed Install restriction Hole in detergent...

Page 22: ...all repair kit when needed Worn packing in pump Install new packing kit Fouled or dirty inlet or discharge valves in pump Clean inlet and discharge valve Worn inlet or discharge valves Replace with va...

Page 23: ...scale 1 Be sure main gas valve gas cock or selector arm is turned on 2 With gas on and system sparking probe terminals PV and 24V GND If pilot gas does not flow with 24 volts at these terminals repla...

Page 24: ...switch on With the pilot burning and the flame on the ignitor sensor rod the main burner should turn on If it does not replace the ignition control unit SHORT CYCLING OF MAIN BURNER MAIN BURNER TURNS...

Page 25: ...ump needs repairing CAUTION When using this procedure to test components keep the spray gun open at all times High Limit Hot Water Thermostat For safety each machine is equipped with a high limit cont...

Page 26: ...installed between pro pane bottle and gas valve Propane Cylinder Capacity An important consideration with propane systems is the capacity of the supply cylinder relative to the needs of the burner The...

Page 27: ...through the coil by whatever means are available for the particular system the water heater is used on To Adjust Pressure Regulator Adjustment of the pressure regulator is not normally necessary since...

Page 28: ...Lbs per Gal Liquid 4 23 4 87 BTU per Cu Ft Vapor 2 563 3 39 BTU per Gal Liquid 91 547 102 032 BTU per Lb Liquid 21 591 21 221 Cu Ft per Lb Liquid 8 607 6 53 Cu Ft per Gal Liquid 36 45 31 8 Octane Numb...

Page 29: ...essure gauge At the lower levels it is expressed in water column inches i e 11 w c i Higher pressures are expressed in terms of the force exerted against a square inch of area for example 125 lbs per...

Page 30: ...e life of your pressure washer Perform maintenance more often under severe conditions MAINTENANCE SCHEDULE Replace Fuel Lines Annually Pump Oil Inspect Daily inspect the oil level Change After first 5...