2. Other panel installation methods
surface panel
panel
Stainless steel panel
Curved panel
Filter strip
1. Unscrew the fixing screws on the filter strip and remove the
filter strip.
2. Connect the induction eye and the power pair wiring in the
main box.
3. Align the two mounting holes on the panel with the two
mounting holes in the middle of the host bottom box, and then fix
the panel on the host bottom box with m4x40mm round head
screws.
4. Install the filter strip back on the panel and fix it with
m2.5x6mm screws
1) Suck out the stainless steel panel on the face frame with a suction
cup.
2) Connect the electric eye and the power pair wiring in the main box
3) Align the two mounting holes on the face frame with the two mounting
holes in the middle of the host bottom box, and then fix the face frame
on the host bottom box with m4x40mm round head screws.
4) Install the stainless steel panel
1.Put the fixing bracket into the wall hole and lock it with the main box
with m4*40 machine thread
2.Plug the red and black plugs of the electric eye on the panel into the
corresponding plugs of the host respectively (for AC and DC products,
the red plug of the battery box in the host box is connected with the red
plug of the power supply)
3.Insert the spring at the bottom of the panel into the hook of the fixed
support, and then press and push the panel into the upper slot of the
support
panel installation
wiring
Mounting bracket
KARAT URINAL SENSOR