VI Instructions
Note:
8.Installation completed
panel
panel
urinal
urinal
ceramic tiles
ceramic tiles
after installation, check the connec-
tion of the power line, and then have
several times try to flush water.
1.Operation method
2.Precautions for operation
1) When the user enters the sensing area, the sensor will conduct the first stage of pre flushing
after sensing for 3 seconds, and then the sensor will be effective after sensing for 3 seconds.
When the user leaves the sensing area for 3 seconds, the second stage of cleaning and
flushing will be carried out (this flushing time can be set by the remote control within 2 seconds
to 15 seconds); If users use it continuously within one minute, the first stage of pre flushing will
not be carried out, and only the second stage of cleaning and flushing will be carried out after
the user leaves (environmental protection and water-saving design). The sensor will be auto-
matically cleaned and flushed once without being used for 24 hours. The sensing distance of
the sensor can be adjusted within the range of 30cm to 80cm; The factory default sensing
distance is set to 55cm.
2) For products with manual pressing function, the users can push the manual button to flush
the urinal when the AC power supply is cut off or the DC battery is exhausted, or other abnor-
malities occur leading to the automatic induction failure.
1)In order to avoid the possibility of failure, do not install the product in front of stainless steel
walls and other high-strength reflective surfaces or other infrared sensors.
2)If you need to use it in special environments such as dark black clothes with high intensity
reflection or easy absorption of infrared rays, please consult the supplier to choose anti color
difference sensor products to achieve the best effect
KARAT URINAL SENSOR