IX Simple fault analysis and elimination
When the sensor has the following appearance, it may not be caused by appliance failure.
Please analyze and eliminate them according to the following table.
Appearance
No water
Cause
Inspection and analysis
Elimination
No stop
of water
Small
amount
of water
The opening of regulat-
ing valve is too small
Impurities in the solenoid
valve
Check whether there is
normal power supply to
the sensor
AC type: connect the
power supply
DC type: replace the
battery
Filter clogged
Filter clogged
Poor connector contact
Abnormal sensing
distance
Whether to adjust
Whether it is loose
or not connected
Abnormal water supply
Check the water source
Turn on the water supply
Adjust with remote control
Tighten all connectors
Clean the filter
Cleaning solenoid valve
Clean the filter
Adjust the regulating valve
counterclockwise
Abnormal power supply
Matters needing attention
In case of failure in operation, please refer to "simple fault analysis and
elimination" for inspection and maintenance. When the fault cannot be
eliminated, it is not recommended that the customer dismantle the
components and parts for maintenance without authorization. Contact
the customer service center or dealer to arrange professionals for
maintenance.