Karat AC Installation And Operation Manual Download Page 12

VIII Maintenance and precautions

2. Adjustment of sensing distance and flushing time

1. Cleaning

2. Clean the filter

3. It is strictly forbidden to wash with water directly

4. Do not use corrosive cleaners

The sensing distance and flushing time of urinal flushing sensor have been set to the best use 
state when leaving the factory. If you need to change it, you can use a special remote control to 
adjust it. For details, please consult the customer service center or dealer of the company

If there are obstacles or dirt in front of the induction 
window that will affect the normal induction, the 
obstacles must be cleared and the induction window 
must be cleaned in time

Adjust the regulating valve to turn off the water 
source with a "-" screwdriver, unscrew the filter, 
clean it with a toothbrush, and then re-install it.

Since the host machine contains electronic control 
circuits, it is strictly forbidden to wash the surface 
directly with water to prevent accidents

Do not use corrosive cleaners so as not to damage 
and affect the appearance when cleaning applianc-
es,because plastic or stainless steel products are 
used for panels and induction windows.

KARAT URINAL SENSOR

Summary of Contents for AC

Page 1: ...Product installation and operation manual KARAT URINAL SENSOR...

Page 2: ...ively eliminate cross infection of bacteria 4 Applicability the product has beautiful appearance simple and convenient installation and is suitable for all kinds of new construction sites and refittin...

Page 3: ...on Integrated pane fixed bracket to match the integrated panel Assembly of mechanical button framed panel face frame to match the framed panel Solenoid valve Protection box Solenoid valve with button...

Page 4: ...Depth of wall excavation 90mm Depth of wall excavation 90mm The ceramic tile surface shall not be lower than the top surface of the protective box The ceramic tile surface shall not be lower than the...

Page 5: ...ng ring must be placed in the union After installation open the water source to confirm that there is no water leakage and then proceed to the next installation work protect the urinal before flushing...

Page 6: ...nlet installation mode ceramic tile protective box Connect to the elbow Install the protective box fill the gap with cement and paste tiles the ceramic tile surface cannot be lower than the top surfac...

Page 7: ...n the top surface of the protective box ceramic tile wall No filler Metal hose back water inlet joint wall urinal urinal draining pipe protective box ceramic tiles ceramic tiles 3 Connect the metal ho...

Page 8: ...l sucked on the face frame 3 Connect the black male plug of the electric eye with the black female plug of the solenoid valve Con nect the red male plug of the power supply or battery box with the red...

Page 9: ...power pair wiring in the main box 3 Align the two mounting holes on the face frame with the two mounting holes in the middle of the host bottom box and then fix the face frame on the host bottom box...

Page 10: ...be carried out after the user leaves environmental protection and water saving design The sensor will be auto matically cleaned and flushed once without being used for 24 hours The sensing distance o...

Page 11: ...ot inductive or the power supply is in poor contact please turn off the power immediately and find relevant professionals for mainte nance to avoid electric shock or other accidents battery box Batter...

Page 12: ...If there are obstacles or dirt in front of the induction window that will affect the normal induction the obstacles must be cleared and the induction window must be cleaned in time Adjust the regulat...

Page 13: ...her to adjust Whether it is loose or not connected Abnormal water supply Check the water source Turn on the water supply Adjust with remote control Tighten all connectors Clean the filter Cleaning sol...

Reviews: