Karat AC Installation And Operation Manual Download Page 2

Thank you for your insight in choosing our urinal flushing sensor. I believe you 
will be immensely pleased after choosing it. From now on, you become a guest 
of our company. We are ready to provide you with high-quality services. In order 
to ensure that this product can give full play to its unique performance and pro-
long its service life, We advise you to read the following content before use to 
ensure that you can use this product normally.

The urinal flush sensor is carefully designed based on the principle of infrared 
induction. It integrates the quality of bureau technology. It has the following ad-
vantages:

1. Intelligence

: automatic sensing, which can distinguish whether the user is 

using the urinal and make a judgment to flush.

2. Automaticity

: the user does not need to take any action within the sensing 

range of the urination sensor to realize flush automatically.

3. Hygiene:

 the function of flushing urinal can be achieved without getting close 

to the appliance, which is convenient and hygienic and Effectively eliminate 
cross infection of bacteria.

4. Applicability

: the product has beautiful appearance, simple and convenient 

installation, and is suitable for all kinds of new construction sites and refitting of 
old projects.

II Product performance parameters

I Product functions and characteristics

Model

AC

DC

AC/DC

Power

Power supply

Nominal diameter

Ambient 

temperature

Induction time

Flushing volume

Induction distance

Applicable water 

pressure

Working:≤4W 

Standby:≤2W

Working:≤4W 

Standby:≤2W

Standby:≤0.2mW

DC6V

AC220V/50Hz DC6V

AC220V/50HZ

Start the device after induction for more than 3 seconds, two-stage flushing

Under static water pressure 0.17 ± 0.01Mpa: flushing volume ≤3L per cycle
55cm, subject to the test of 297mmx297mm wood pulp copy paper

G1/2" (DN15)

0.05~0.6MPa

1-55℃

III Product structure diagram
(The picture is for reference only, and the real object shall prevail)

   Battery box
(only for DC)

G1/2”

inlet G1/2”

G1/2”

inlet G1/2”

G1/2”

inlet G1/2”

Filter 

regulating 

valve

Filter 

regulating 

valve

Manual 

button

Solenoid valve 

without button

Solenoid valve 

with button

Power 

supply

Power 

supply

Host machine 

box

Host 

machine 

box

Coil

Outlet

Coil

Outlet

Automatic model

Manual automatic 

all-in-one model

KARAT URINAL SENSOR

Summary of Contents for AC

Page 1: ...Product installation and operation manual KARAT URINAL SENSOR...

Page 2: ...ively eliminate cross infection of bacteria 4 Applicability the product has beautiful appearance simple and convenient installation and is suitable for all kinds of new construction sites and refittin...

Page 3: ...on Integrated pane fixed bracket to match the integrated panel Assembly of mechanical button framed panel face frame to match the framed panel Solenoid valve Protection box Solenoid valve with button...

Page 4: ...Depth of wall excavation 90mm Depth of wall excavation 90mm The ceramic tile surface shall not be lower than the top surface of the protective box The ceramic tile surface shall not be lower than the...

Page 5: ...ng ring must be placed in the union After installation open the water source to confirm that there is no water leakage and then proceed to the next installation work protect the urinal before flushing...

Page 6: ...nlet installation mode ceramic tile protective box Connect to the elbow Install the protective box fill the gap with cement and paste tiles the ceramic tile surface cannot be lower than the top surfac...

Page 7: ...n the top surface of the protective box ceramic tile wall No filler Metal hose back water inlet joint wall urinal urinal draining pipe protective box ceramic tiles ceramic tiles 3 Connect the metal ho...

Page 8: ...l sucked on the face frame 3 Connect the black male plug of the electric eye with the black female plug of the solenoid valve Con nect the red male plug of the power supply or battery box with the red...

Page 9: ...power pair wiring in the main box 3 Align the two mounting holes on the face frame with the two mounting holes in the middle of the host bottom box and then fix the face frame on the host bottom box...

Page 10: ...be carried out after the user leaves environmental protection and water saving design The sensor will be auto matically cleaned and flushed once without being used for 24 hours The sensing distance o...

Page 11: ...ot inductive or the power supply is in poor contact please turn off the power immediately and find relevant professionals for mainte nance to avoid electric shock or other accidents battery box Batter...

Page 12: ...If there are obstacles or dirt in front of the induction window that will affect the normal induction the obstacles must be cleared and the induction window must be cleaned in time Adjust the regulat...

Page 13: ...her to adjust Whether it is loose or not connected Abnormal water supply Check the water source Turn on the water supply Adjust with remote control Tighten all connectors Clean the filter Cleaning sol...

Reviews: