T600 Tag Tester
DOC#:
UM 360420-835
REVISION F
P
age 24 of 55
© Kapsch TrafficCom Canada Inc. 2022
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict confidence
and will be kept confidential and used solely for the purpose intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or used as the basis for
manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE:UM 360420-835 REV F, T600 OPERATOR AND MAINTENANCE MANUAL.DOCX 03/28/2022 3:02
Kapsch TrafficCom
Understanding the T600 test data
A variety of information about the OBU is displayed in the Test Results area after a test.
Table 3-1: Burst Test Read Results Explained
Read Result field
Information displayed
Successes
The number of successful reads during the burst test.
Fail CRC
The number of reads that failed as a result of a bad CRC.
Fail timeout
The number of reads that failed as a result of an OBU not
communicating within the allowable time.
Table 3-2: Burst Test Write Results Explained
Write Result field
Information displayed
Successes
The number of successful writes during the burst test.
Fail CRC
The number of writes that failed as a result of a bad CRC.
Fail timeout
The number of writes that failed as a result of an OBU not
communicating within the allowable time.
Fail verify
The number of writes that failed because a successful write could
not be confirmed.
Table 3-3: Margin Test Results Explained
Margin field
Information displayed
Read
The attenuation value, between 0 and 15 dB, that allows the OBU to
be read successfully.
Write
The attenuation value, between 0 and 15 dB, that allows the OBU to
be written to successfully.