T600 Tag Tester
DOC#:
UM 360420-835
REVISION F
Page 41 of 55
© Kapsch TrafficCom Canada Inc. 2022
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict confidence
and will be kept confidential and used solely for the purpose intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or used as the basis for
manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: UM 360420-835 REV F, T600 OPERATOR AND MAINTENANCE MANUAL.DOCX 03/28/2022 3:02
Kapsch TrafficCom
Tag Type
Name
Type #
Calibration File
Remarks
Exterior OBU
FME
2
T600 <s/n> Exterior
OBU calibration
history file.cal
Replaces older
model LPT.
Identified by tag
serial#.
Toll / Balance
3
T600 <s/n> Toll Tag
calibration history
file.cal
HOT / HOV
6
T600 <s/n> HOT
calibration history
file.cal
Note
: It is required to specify the range of the tag serial# for the new model in the agency mapping file (T600Cfg.xml)
in order for the application to pick the correct tag type and the required calibration file for testing.
How to identify Interior OBU (G4E) from the older model FPT (G3B)
Since the Interior OBU (G4E) and the older model FPT (G3B) share the same type# (0), use the tag serial number to
differentiate them.
Open Microsoft WordPad.
In WordPad, open T600Cfg.xml.
Note
:
T600Cfg.xml
is located in the same directory as the executable
T600TagTester.exe
.
To specify the tag serial number range for G4E model, go to the appropriate Agency ID to make the changes. Refer
to the Examples below.
On the line with Tag Model="G4E", change the field value of
SerialNum_Start
and
SerialNum_End
to the start and
end of the tag serial number which are non-zero for the G4E model respectively.
Note
: If there are multiple serial number ranges, use multiple lines with each line specifying one number range.
Click
Save
in WordPad to save the file
Restart T600 application,
T600TagTester.exe
, for the new settings to take effect.
Note
: If the agency mapping file is not found, or corrupted when the application starts, a new file will be generated
with
“0” as the default value of
SerialNum_Start
and
SerialNum_End
for the G4E model for all agencies. This means
that all tags with type# 0 will be identified as the old model FPT (G3B).
How to identify Exterior OBU (FME) from the older model LPT
Since the Exterior OBU (FME) and the older model LPT share the same type# (2), use the tag serial number to
differentiate them.