108
Kanuk GmbH • Hauptstraße 131 • 01744 Dippoldiswalde
EN
KanUK OrIGInal
tecHnical Data anD Dimen�ion�
Emissions
Kanuk® Original stoves meet the requirements of the first BImSchV stage 2, as well as according to Austrian law Art.
15a B-VG and can be operated as room heaters with flat firing without any restrictions or retrofitting.
Type plate
The type plate is located on the radiation protection plate on the back of the stove and must not be removed. This
confirms the inspection of the stove and is necessary for the acceptance, as well as annual inspection of the chim-
ney sweep.
technIcal Data anD DIMensIOns
Kanuk® Original
7 kW
9,5 kW
10 kW
13 kW
Nominal power (kW)
6,7
9,5
10,3
12,7
Room heating capacity (m³)*
180
244
280
325
Flue pipe connection (mm)
120
120
160
160
Dimensions H x W x D (cm)
63 x 45 x 69
63 x 45 x 69
67 x 54 x 82
67 x 54 x 82
Efficiency (%)
85,5
86,6
83,4
81,1
Viewing window (cm)
24 x 14
24 x 14
24 x 14
24 x 14
Exhaust gas temperature Ø (°C)
171
177
198
180
Triple point temp.(°C)
171
253
227
278
Max. Log length (cm)
25
25
36
36
Exhaust gas mass flow (g/s)
6,74
8,44
10,77
16,75
Weight (kg)
74
74
107
107
Minimum chimney draught (Pa)
12
12
15
16
Outside air connection (mm)
80
80
100
100
DIN EN number
DIN EN
13240:2005-10
DIN EN
13240:2005-10
DIN EN
13240:2005-10
DIN EN
13240:2005-10
Operating mode closed
Primary, secondary air
Window rinsing
Logs, wood briquettes
1st BImSchV Level 2
AT §15a B-VG Standard
CE Mark
* depending on building fabric, insulation, etc.
Errors, misprints and technical changes reserved.
Summary of Contents for Bank
Page 1: ...BEDIENUNGSANLEITUNG MODE D EMPLOI INSTRUCTION MANUAL...
Page 4: ......
Page 5: ...BEDIENUNGSANLEITUNG Dieses Produkt eignet sich nicht als Hauptheizger t...
Page 24: ......
Page 25: ...BEDIENUNGSANLEITUNG Dieses Produkt eignet sich nicht als Hauptheizger t...
Page 51: ...Kanuk GmbH Hauptstra e 131 01744 Dippoldiswalde 51 DE Kanuk Design Eco Design...
Page 54: ......
Page 55: ...MODE D EMPLOI Ce produit ne convient pas comme appareil de chauffage principal...
Page 74: ......
Page 75: ...MODE D EMPLOI Ce produit ne convient pas comme appareil de chauffage principal...
Page 101: ...Kanuk GmbH Hauptstra e 131 01744 Dippoldiswalde 101 FR Kanuk Design Eco Design...
Page 104: ......
Page 105: ...INSTRUCTION MANUAL This product is not suitable as a main heater...
Page 124: ......
Page 125: ...INSTRUCTION MANUAL This product is not suitable as a main heater...
Page 151: ...Kanuk GmbH Hauptstra e 131 01744 Dippoldiswalde 151 EN Kanuk Design Eco Design...