126
Kanuk GmbH • Hauptstraße 131 • 01744 Dippoldiswalde
EN
KanUK DesIGn
imPortant information
KanUK DesIGn
IMPOrtant InFOrMatIOn
Installation site
Keep the following distances from combustible materials, otherwise there is a risk of fire.
Kanuk® Design
forward
lateral
backwards
upwards
Bank, Hang, Stand, Tower,
Tube, Wave
100 cm
30 cm
30 cm
75 cm
Kanuk® Design
forward
lateral with
*sp
lateral wit-
hout *sp
backwards
To the ground
upwards
LuTo XV
80 cm
55 cm
90 cm
50 cm
25 cm
75 cm
LuTo VIII
80 cm
40 cm
60 cm
25 cm
0 cm
75 cm
LuTo VIII Tower
80 cm
40 cm
60 cm
25 cm
0 cm
75 cm
* sp = side plate
Errors, misprints and technical changes reserved.
Combustible floor coverings must be fully protected by fireproof material. In addition, this material must be laid at
least 50 cm to the front and at least 30 cm to the side of the firing chamber. Make sure that the subfloor has a load-
bearing capacity suitable for the furnace and, if applicable, the subframe.
note:
Be careful that the stove gets hot during operation, which may result in a burn hazard. Do not touch the
viewing pane and the outer surfaces!
see table
see table
see table
see table
30 cm
50 cm
30 cm
Combustion air supply
For Kanuk® Design stoves, the combustion air supply is sufficient if the room where the stove is installed has at least
one door to the outside or a window. The window/door should be able to be opened and have a cross-section of at
least 150 cm². The installation room should have a volume of at least 4 m³ per kW of nominal heat output.
Summary of Contents for Bank
Page 1: ...BEDIENUNGSANLEITUNG MODE D EMPLOI INSTRUCTION MANUAL...
Page 4: ......
Page 5: ...BEDIENUNGSANLEITUNG Dieses Produkt eignet sich nicht als Hauptheizger t...
Page 24: ......
Page 25: ...BEDIENUNGSANLEITUNG Dieses Produkt eignet sich nicht als Hauptheizger t...
Page 51: ...Kanuk GmbH Hauptstra e 131 01744 Dippoldiswalde 51 DE Kanuk Design Eco Design...
Page 54: ......
Page 55: ...MODE D EMPLOI Ce produit ne convient pas comme appareil de chauffage principal...
Page 74: ......
Page 75: ...MODE D EMPLOI Ce produit ne convient pas comme appareil de chauffage principal...
Page 101: ...Kanuk GmbH Hauptstra e 131 01744 Dippoldiswalde 101 FR Kanuk Design Eco Design...
Page 104: ......
Page 105: ...INSTRUCTION MANUAL This product is not suitable as a main heater...
Page 124: ......
Page 125: ...INSTRUCTION MANUAL This product is not suitable as a main heater...
Page 151: ...Kanuk GmbH Hauptstra e 131 01744 Dippoldiswalde 151 EN Kanuk Design Eco Design...