Kanuk GmbH • Hauptstraße 131 • 01744 Dippoldiswalde
141
EN
KanUK DesIGn
oPeration anD maintenance
OPeratIOn anD MaIntenance
Combustion air control
Bank, hang, stand, tower, tube, Wave:
Kanuk® Design furnaces are equipped with primary and secondary air openings (see illustration) for combustion air
supply. During start-up and operation with Nominal heat output, both dampers must be open. The secondary air
damper is used primarily for window rinsing and should be fully or partially closed only for ember retention. Closing
the secondary air damper throttles the combustion air supply, which may increase emissions. Secondary air ope-
nings cannot be fully closed for safety reasons.
Primary air control
Secondary air control
Kanuk Design luto:
The Kanuk Design LuTo is equipped with a primary air opening for combus-
tion air supply. The damper must be open during start-up and operation
with Nominal heat output. To maintain embers and reduce combustion air,
the damper can be fully or partially closed. Moving the primary air control
towards the furnace closes the primary air damper and the combustion air
supply is throttled, which may increase emissions.
Ash
Bank, hang, stand, tower, tube, Wave:
Combustion residues fall through the ceramic grate integrated in the combustion chamber floor into the ash box
located under the floor, which can be easily pulled out for cleaning. Be sure to empty only cold ash and dispose of it
in closed, non-combustible containers. Hot ash or pieces of embers in the ash could otherwise cause a fire.
Kanuk Design luto:
The Kanuk Design LuTo stove does not have a grate or ash
pan. Combustion residues may only remain in the stove until
they reach the top edge of the first ceramic. It is not necessa-
ry to remove the ash without leaving any residue.
Cleaning
The flue gas conducting parts as well as the connecting pieces must be cleaned if they are dirty. Irrespective of this,
cleaning must be carried out at least once during and after the heating period. The sealing cord of the firebox door
must be replaced if damaged.
Primary air control
Summary of Contents for Bank
Page 1: ...BEDIENUNGSANLEITUNG MODE D EMPLOI INSTRUCTION MANUAL...
Page 4: ......
Page 5: ...BEDIENUNGSANLEITUNG Dieses Produkt eignet sich nicht als Hauptheizger t...
Page 24: ......
Page 25: ...BEDIENUNGSANLEITUNG Dieses Produkt eignet sich nicht als Hauptheizger t...
Page 51: ...Kanuk GmbH Hauptstra e 131 01744 Dippoldiswalde 51 DE Kanuk Design Eco Design...
Page 54: ......
Page 55: ...MODE D EMPLOI Ce produit ne convient pas comme appareil de chauffage principal...
Page 74: ......
Page 75: ...MODE D EMPLOI Ce produit ne convient pas comme appareil de chauffage principal...
Page 101: ...Kanuk GmbH Hauptstra e 131 01744 Dippoldiswalde 101 FR Kanuk Design Eco Design...
Page 104: ......
Page 105: ...INSTRUCTION MANUAL This product is not suitable as a main heater...
Page 124: ......
Page 125: ...INSTRUCTION MANUAL This product is not suitable as a main heater...
Page 151: ...Kanuk GmbH Hauptstra e 131 01744 Dippoldiswalde 151 EN Kanuk Design Eco Design...