COMMANDS
52
Xflow
ON | OFF
default ON
All Units
All Modes
When ON software flow control will be implemented according to the settings of START, STOP,
XON, XOFF. For normal software flow control set XFLOW ON, START $11, STOP $13, XON $11,
XOFF $13. The TNC expects the computer or terminal to respond to the flow control characters
XON and XOFF and the TNC responds to the START and STOP characters from the computer.
When OFF, the TNC will only use and recognize hardware flow control lines (CTS and RTS) to start
and stop data. The RS-232 cable must be wired appropriately. If the software flow control charac-
ters are set to $00, software flow control is not possible.
In the Transparent Mode, flow control is also determined by the settings of TRFLOW and TXFLOW.
See also: start, stop, trflow, txflow, xoff, xon
XMitecho
ON | OFF
default OFF
KAM
CW/RTTY/ASCII/AMTOR
When ON, characters are echoed when they are sent to the transceiver for output. When OFF,
echo is immediate.
XMITOk
ON | OFF
default ON
KPC-1
/
KPC-2
/
KPC-2400
All Modes
default ON/ON
KAM
All Modes
When ON, transmitting functions are enabled. If turned OFF, transmitting is inhibited while all oth-
er functions of the TNC are unchanged.
XOff
n
(n = $00 – $FF)
default $13 (Ctrl-S)
All Units
All Modes
This command selects the character sent by the TNC to the computer to stop input from the com-
puter. If set to $00 hardware flow control must be used. For software flow control set this parame-
ter to the character the computer expects to see to stop sending data to the TNC.
See also: xflow, xon
XON
n
(n = $00 – $FF)
default $11 (Ctrl-Q)
All Units
All Modes
This command selects the character sent by the TNC to the Computer to restart input from that
device. If set to $00 hardware flow control must be used. For software flow control set this param-
eter to the character the computer expects to see to restart sending data to the TNC.
See also: xflow, xoff