DN1670-1609
16
16.Click on the
IP Device Parameters
tab.
17.Verify the
Encryption key
. A random key is generated automatically.
18.Select the
Controller’s loop baud rate
.
Note:
The maximum baud rate for the KT-200 controller is 19200.
19.The settings in the
Delays
section refer to the communication with the Gateway. In order to display
the connection status of the IP Link with EntraPass and to avoid large amount of traffic, the IP Link
sends a heartbeat to EntraPass at a pre-configured interval (60 seconds for example). If EntraPass
is not answering after this amount of time, the IP Link will retry several times and then stop the polling
if no answer is received.
•
Heartbeat frequency (mm:ss)
: The time range value is from 0:15 to 10:00. This is the heartbeat
frequency from the IP Link to the Gateway.
•
Fail to report after (mm:ss)
: The time range value is from 3:00 to 59:59. This is the time that the
Gateway will wait before declaring IP Link communication failed.
•
Fail-soft delay on gateway communication failure (mm:ss): The maximum time range value will
follow the selection from the Heartbeat Frequency. This is the time that the IP Link will take to
verify if there is a communication failure with the Gateway before it operates in stand-alone
mode.
•
Retry count: The range value is 1 to 15. This is the number of times that the IP Link will retry to
confirm communication failure with the Gateway.
•
Maximum wait on send command (s:cc): The time range value is from 1:00 to 9:99. This is the
maximum time allowed for the IP Link to acknowledge a command sent from the EntraPass
workstation.
20.Click on the floppy icon to save. Click on
Close
.
Summary of Contents for IP Link
Page 2: ......
Page 4: ...DN1670 1609 ii ...
Page 31: ...27 DN1670 1609 ...
Page 32: ...DN1670 1609 28 ...
Page 34: ......
Page 37: ...DN1670 1609 ...