P r o g r a m m i n g I o P a s s ™ - S t e p b y S t e p
- Viewing Cards
20
To Add/Delete a group of cards:
1.
Enter the master password (default is [111111]) fol-
lowed by the [#] key. The LCD displays the follow-
ing:
1. ENROLL
2. PASSWD
3. TIMER
4. SYSTEM
2.
Press [1-Enroll]. The LCD displays:
1-ACCESS CARD
2-AUX. CARD
3.
Press [1-Access Card]. The LCD displays:
1. PROGRAM CARDS
2. VIEW CARDS
4.
Press [1-Program Cards]. The LCD displays:
1. S_ADD
2. S_DEL
3. B_ADD
4. B_DEL
5.
Press [3-B_Add] to add cards or [4-B_Del] to delete a
batch of cards. The LCD displays:
TOTAL CARDS: XX
(xx=#cards in unit)
CARD NO.__:______
6.
There are two ways to enter the card number in the
system:
• You can simply present the card to the reader and the
number will automatically be entered.
• enter the card number manually followed by the [#].
To enter special characters (hexadecimal) refer to the
section “Special Characters (Hexadecimal)” (page
19).
7.
Once you have entered the first card number, the
LCD will display the following screen:
CARD NO. XX:XXXXX
TOTAL:
8.
Enter the total number of sequential cards that you
wish to add/delete followed by the [#] key to accept.
The LCD will display:
Processing...xx
For example
if you wanted to add 250 cards that are
sequentially numbered you would enter the first card
(lowest) number and then select 250 for the total. If
for example you enter [01:00001] as the first card
number, the system would automatically program
cards [01:00001] to [01:00250] into the system.
NOTE:
Cards that were enrolled in the unit using the “batch
mode” will function without having to enter the PIN, even if
the mode is selected. You will have to enter the PINs using
the Single Add feature. When you delete a card, the PIN
associated with the card is also deleted.
5.4.3 - Adding & Deleting Auxiliary Cards
Auxiliary cards are used to activate an external device
without unlocking the door. For more information, refer to
“5.8 Auxiliary Function Configuration (Relay-1)”, page
22.
To Add/delete Auxiliary Cards:
1.
Enter the master password (default is [111111]) fol-
lowed by the [#] key. The LCD displays the follow-
ing:
1. ENROLL
2. PASSWD
3. TIMER
4. SYSTEM
2.
Press [1-Enroll]. The LCD displays:
1-ACCESS CARD
2-AUX.CARD
3.
Press [2-Aux.Card]. The LCD displays:
1. PROGRAM CARDS
2. VIEW CARDS
4.
Press [1-Program Cards]. The LCD displays:
1. S_ADD
2. S_DEL
5.
Press [1-S_Add] to add a card or [2-S_Del] to delete
a card. The LCD displays:
TOTAL CARDS: XX
CARD NO.__:______
6.
Enter the card number in the system by simply
presenting the card to the reader, or by entering the
card number manually followed by the [#]; to enter
special characters refer to “Special Characters
(Hexadecimal)” (page 19).
7.
Once you have entered the card number, the LCD
will display:
ACCEPTED
8.
Once the card has been accepted, the system will
return to the add/delete card screen. To add or delete
another card simply repeat steps 5 and up. To exit the
programming mode press [#], [#].
5.5
Viewing Cards
You may view the cards that are programmed in the unit’s
memory. These are sorted based or their programming
order within the unit. For example, if cards numbered
01:00000 to 01:00005 are programmed and you delete the
card number 01:00004, when you add a new card (for
example 01:00009), it is placed where the last card was
deleted: 01:00000, 01:00001, 01:00002, 01:00003,
01:00009
, 01:00005.
1.
Enter the master password (default is [111111]) fol-
lowed by the [#] key. The LCD displays the follow-
ing:
1. ENROLL
2. PASSWD
3. TIMER
4. SYSTEM
2.
Press [1-Enroll]. The LCD displays:
1-ACCESS CARD
2-AUX. CARD
Summary of Contents for IoPass SA-500
Page 4: ......
Page 6: ...vi ...
Page 12: ...Installing and Wiring IoPass Connecting the Power 12 General Wiring Diagram ...
Page 14: ...Programming IoPass Introduction IoPass Factory Defaults 14 ...
Page 33: ...Programming IoPass Step by Step Resetting the IoPass Unit to Factory Defaults 33 ...
Page 34: ...Programming IoPass Step by Step Resetting the IoPass Unit to Factory Defaults 34 ...
Page 35: ......