5.4

Adding & Deleting Cards

Up to 5,000 cards can be stored in the unit (plus 20 
auxiliary cards).

NOTE: 

Once you have selected the “Access Mode”, you 

may start enrolling cards. Otherwise, please refer to 
“Access Mode Selection” (page 15).

Use the provided “Card Information Record Sheet” (page 
30) t
o store user information (card number, name and PIN 
if applicable). Also, if you are using the PIN feature, you 
may want to gather the PIN from cardholders in advance.
All new cards must be enrolled into the unit before access 
is allowed. Up to 5,000 cards can be stored in the unit (plus 
20 auxiliary cards). 
Cards are stored based on their programming sequence 
within the unit. If a card that is not enrolled is presented to 
the reader, the message INVALID CARD is displayed. 

NOTE: 

Depending on how many cards you need to 

program, you can simply add them one at a time or use the 
batch process to add a pre-selected batch of cards in the 
unit.  

If the maximum number of cards (access/auxiliary) has 
been reached, the message NO SPACE will be displayed 
each time you attempt to add a new card:

5.4.1 - Single Add/Single Deletion

To add/delete a single card:

1.

Enter the master password (default is [111111]) fol-
lowed by the [#] key. The LCD displays the follow-
ing:

1. ENROLL

2. PASSWD

3. TIMER

4. SYSTEM

2.

Press [1-Enroll]. The LCD displays:

1-ACCESS CARD

2-AUX. CARD

3.

Press [1-Access Card]. The LCD displays:

1. PROGRAM CARDS

2. VIEW CARDS

4.

Press [1-Program Cards]. The LCD displays:

1. S_ADD

2. S_DEL

3. B_ADD

4. B_DEL

5.

Press:

• [1-S_Add] to add a new card, or 
• [2-S_Del] to delete a card from the unit.

The LCD displays:

TOTAL CARDS: XX (xx=# of cards in

unit)

CARD NO.__:______

6.

There are two ways to enter the card number in the 
system:

• You can simply present the card to the reader and the 

number will automatically be entered.

• You can type in the number (XX:XXXXX) printed on 

the card followed by the [#] sign using the keypad. If 
you need to enter special characters (hexadecimal) 
see “Special Characters (Hexadecimal)” below, OR 

7.

Once you have entered the card number, you will see 
the following screen:

CARD NO. XX:XXXX

PIN:

OR

ALREADY USED

PIN:

8.

To enter the PIN, enter the 4-digit code using the 
keypad. Use the [#] key to accept;

NOTE: 

If you leave the PIN blank, the unit will assume that 

no PIN was entered and the user will not be prompted for 
his PIN.

9.

Once the card has been accepted, the system will 
display:

ACCEPTED

10.

Following the acceptance message, the unit will 
display the add/delete card screen. To add/delete 
another card simply repeat steps 5 and up. 

11.

To exit the programming mode press [#], [#].

5.4.2 - Batch Add/Batch Deletion

Before you can use the batch mode to enroll new cards, it 
is essential that the group of cards be numbered 
sequentially.

Special Characters (Hexadecimal)

When inputting the card number using the keypad, 
you may need to program special characters. You can 
do this using hexadecimal digits. The following 
hexadecimal digits will insert special characters into 
the card number. To program a hexadecimal digit 
press [*], then press the number corresponding to the 
hexadecimal digit.
• For A press [0]
• For B press [1]
• For C press [2]
• For D press [3]
• For E press [4]
• For F press [5]
If another hexadecimal digit is required, press [*] 
again, then press the corresponding number. The 
IoPass will return to decimal programming on the next 
digit.
Example: To program “4E”, you would enter:
• [4] - programs a “4”
• [*][4] - programs an “E”

Summary of Contents for IoPass SA-500

Page 1: ...on on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be carefully read IoPass Stand Alone Door Controller Installation Manual DN1445 0303 V 2 22 ...

Page 2: ... of insuffi cient coverage disconnecting a device immediately following a per son through the controlled gate or door or interfering with the proper operation of the system Power Failure Control units intrusion detectors smoke detectors and many other security devices require an adequate power supply for proper opera tion If a device operates from batteries it is possible for the batteries to fail...

Page 3: ...Systems s liability for failure to repair the product under this warranty after a reasonable number of attempts will be limited to a replacement of the product as the exclusive remedy for breach of war ranty Under no circumstances shall Kantech Systems be liable for any special incidental or consequential damages based upon breach of warranty breach of contract negligence strict liability or any o...

Page 4: ......

Page 5: ...2 Modifying the Main Password 18 5 3 3 Modifying the Auxiliary Password 18 5 3 4 Modifying the Guard Password 18 5 4 Adding Deleting Cards 19 5 4 1 Single Add Single Deletion 19 5 4 2 Batch Add Batch Deletion 19 5 4 3 Adding Deleting Auxiliary Cards 20 5 5 Viewing Cards 20 5 6 Verifying a Card Number 21 5 7 Guard Function Configuration Relay 1 21 5 7 1 Enabling the Guard Function 21 5 7 2 Arming D...

Page 6: ...vi ...

Page 7: ... the IoPass firmware as of version 2 22 The new features include 1 Reset function you can clear the IoPass memory and reset it to factory default values 2 View function you can view the next and previous card access and auxiliary card programmed in the system 3 Custom language selection the IoPass unit can be operated in five languages English French Spanish German and Dutch 4 More transaction in ...

Page 8: ...ndicator Bicolor green red Operating temperatures 0 C to 50 C 32 F to 122 F Operating humidity 5 to 95 relative humidity non condensing Door contact input NO or NC selectable Request to Exit input NO or NC selectable Relay output Strike Alarm and Relay 1 relay Form C NO and NC 3A 24VDC Strike Alarm and Relay 1 timer 1 to 255 sec Door ajar timer 1 to 255 sec Audit trail On unit last 380 transaction...

Page 9: ...tact recommended Locking device required Door alarm or annunciator recommended T Rex Request to Exit detector recommended 2 3 Selecting a Mounting Location Select a mounting location for the unit using the following guidelines Close to the door being supervised Away from areas with a large amount of background noise It is recommended that you mount the unit so that the LCD is visible to users when...

Page 10: ...ng the Door Locking Device To install the door locking device refer to the manufacturer s instructions To connect it refer to the diagram below Wiring Diagram 2 8 Connecting the T Rex Exit Detector or Exit Button To install the T Rex Exit Detector push button refer to the manufacturer s instructions To connect it refer to the diagram below Wiring Diagram 2 9 Connecting the Door Contact To install ...

Page 11: ...For more information on the relay function please refer to Relay 1 Functions page 15 Jumper Settings 2 12Connecting the Power Once all other wiring is complete power up the unit Wiring Diagram NOTE Once all connections are finished you may start to program the unit Before you do so we recommend you read the section called Programming IoPass Introduction page 13 Relay 1 Function Function 1 2 3 DURE...

Page 12: ...Installing and Wiring IoPass Connecting the Power 12 General Wiring Diagram ...

Page 13: ...bled See p 23 Auxiliary function Disabled See p 22 Auxiliary password 1234567 default when enabled See p 18 Guard function Disabled See p 21 Guard password 123 default when enabled See p 18 Tamper alarm func tion Disabled See p 23 Forced entry alarm function Enabled See p 24 Door ajar Enabled See p 24 Alarm relay acti vated on door ajar Disabled See p 24 Incorrect PIN keyed in incorrectly five tim...

Page 14: ...Programming IoPass Introduction IoPass Factory Defaults 14 ...

Page 15: ...0 5 5 Viewing Cards page 20 5 6 Verifying a Card Number page 21 4 4 Relay 1 Functions The Relay 1 located on the relay module function depends on your requirements There are three 3 possibilities but ONLY ONE can be configured Depending on your choice the jumpers of the relay module need to be set up accordingly Guard Function This function is used to arm dis arm the connected security system Eith...

Page 16: ...e keypad are used NOTE Please refer to 5 14 Beeper Key Tone Configuration page 26 for more information 4 11 Loop Type Selection The IoPass unit allows the installer to modify the loop type of the exit button and door contact These normally open contacts can be modified to normally closed to suit installer s requirements NOTE For more information refer to 5 15 Loop Type Configuration page 26 4 12St...

Page 17: ...ure the keypad can be accessed by cardholders if you are using this mode Mode 2 Card only OR main password only This mode will require that the user presents his card to the reader to be granted access OR enters his main password using the keypad to be granted access To Select an Access Mode 1 Enter the master password default is 111111 NOTE It is strongly recommended to modify the default passwor...

Page 18: ...o activate the auxiliary relay To Modify the Auxiliary Password 1 Enter the master password default is 111111 then The LCD displays the following 1 ENROLL 2 PASSWD 3 TIMER 4 SYSTEM 2 Press 2 Passwd The LCD displays the following 1 MASTER 2 MAIN 3 AUX CR 4 GUARD 3 Press 3 Aux Cr The LCD displays the default password and invites you to enter a new one Current 1234567 New 4 Enter the new auxiliary pa...

Page 19: ...it The LCD displays TOTAL CARDS XX xx of cards in unit CARD NO __ ______ 6 There are two ways to enter the card number in the system You can simply present the card to the reader and the number will automatically be entered You can type in the number XX XXXXX printed on the card followed by the sign using the keypad If you need to enter special characters hexadecimal see Special Characters Hexadec...

Page 20: ...re When you delete a card the PIN associated with the card is also deleted 5 4 3 Adding Deleting Auxiliary Cards Auxiliary cards are used to activate an external device without unlocking the door For more information refer to 5 8 Auxiliary Function Configuration Relay 1 page 22 To Add delete Auxiliary Cards 1 Enter the master password default is 111111 fol lowed by the key The LCD displays the fol...

Page 21: ...unction page 21 Modify guard code Refer to To Modify the Guard Password page 18 5 7 1 Enabling the Guard Function To enable the guard function 1 Enter the master password default is 111111 fol lowed by the key The unit displays the following 1 ENROLL 2 PASSWD 3 TIMER 4 SYSTEM 2 Press 4 System The LCD displays 1 ALARM 2 CHECK 3 MODE 4 OTHER 3 Press 4 Other The LCD displays 1 TONE 2 DURESS 3 MORE 4 ...

Page 22: ...Up 2 Down 5 8 Auxiliary Function Configuration Relay 1 The auxiliary function is used to trigger a device without unlocking the door The auxiliary relay can be used to activate such devices as lighting control HVAC control or to unlock an auxiliary door The system will either accept an auxiliary card or the auxiliary code to activate the relay NOTE The relay will be activated for a period of 3 sec...

Page 23: ...g and program a value between 1 255 seconds 1 To enter the programming mode enter the master password default is 111111 followed by the key The LCD displays the following 1 ENROLL 2 PASSWD 3 TIMER 4 SYSTEM 2 Press 3 Timer The LCD displays 1 STRIKE 2 ALARM 3 DURESS 4 AJAR 3 Press 3 Duress The LCD displays CURRENT 10 SEC NEW 4 Using the keypad enter the number of seconds during which the duress rela...

Page 24: ...ode is displayed Pressing this key will toggle between selections When required mode is displayed press to save and exit 5 11 2 Using the Force Entry Function Follow this procedure to STOP the force entry alarm if it has been activated 1 When the force entry has been activated the alarm relay will be triggered usually an annunciator and the LCD will display READY FOR CARD FORCE ENTRY 2 This Force ...

Page 25: ... Ajar Function Depending if the door ajar function is configured to trigger the alarm relay follow this procedure to STOP the warning device 1 When the door is left opened the alarm relay will be triggered OR the unit s piezo will sound The LCD will display READY FOR CARD DOOR OPEN 2 The Door Open message is displayed and blinking and will remain on the LCD until the door is closed properly 5 13PI...

Page 26: ...n and door contact These normally open contacts can be modified to normally closed to suit installer s requirements To configure the loop type 1 Enter the master password default is 111111 fol lowed by the key The LCD displays the follow ing 1 ENROLL 2 PASSWD 3 TIMER 4 SYSTEM 2 Press 4 System The LCD displays 1 ALARM 2 CHECK 3 MODE 4 OTHER 3 Press 3 Mode The LCD displays 1 ACCESS MODE 2 DOOR_INPUT...

Page 27: ...o clear the memory the master password is required A double confirmation is used to confirm memory deletion 1 Enter the master password default is 111111 fol lowed by the key The LCD displays the follow ing 1 ENROLL 2 PASSWD 3 TIMER 4 SYSTEM 2 Press 4 System The LCD displays 1 ALARM 2 CHECK 3 MODE 4 OTHER 3 Press 4 Other The LCD displays 1 TONE 2 DURESS 3 MORE 4 LANGUAGE 4 Press 3 More The LCD dis...

Page 28: ...CARDS 1 S_ADD VIEW CARDS 2 S_DEL 2 PASSWD 1 MASTER 2 MAIN 3 AUX CR 4 GUARD 3 TIMER 1 STRIKE 2 ALARM 3 DURESS 4 AJAR 4 SYSTEM 1 ALARM 1 TAMPER 2 FORCE 3 D_AJAR 1 DOOR TIMER 2 ALARM RELAY 4 P_ERR 2 CHECK 1 CHECK CARD NO 2 RECORD CHECK 3 MODE 1 ACCESS MODE 2 DOOR_INPUT 1 EXIT BUTTON 2 DOOR 4 OTHER 1 TONE 2 DURESS 3 MORE 1 GUARD 1 GUARD FUNCTION 4 LANGUAGE 2 STRIKE ACTIVE 1 ENABLE 2 DISABLE 2 AUX CARD...

Page 29: ...ramming mode To enter programming mode enter your 6 digit master password i e 111111 followed by the key Passwords Default New Master 2 1 111111 I__I__I__I__I__I__I Main 2 2 1234 I__I__I__I__I Auxiliary 2 3 1234567 I__I__I__I__I__I__I__I Guard 2 4 123 I__I__I__I Timers Default New Strike relay 3 1 10 seconds I__I__I__I Alarm relay 3 2 10 seconds I__I__I__I Door ajar 3 4 20 seconds I__I__I__I Dures...

Page 30: ...___I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I_____I_____I_____I_____I I_____I_____I_____I_____I I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I I_____I_____I I_____I_____I_____I_____I_____I I_____I_____I_____I_____I I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I__...

Page 31: ... the LCD will display a Time Out message and return to the normal greeting screen 4 The relay will be triggered and the system will disarm Depending on how the system is set up the strike may activate or deactivate 5 The LCD will return to the normal greeting display and the red LED will not flash When the door unlocks access is granted instantly When the door remains locked you must present your ...

Page 32: ...rly Once the function is enabled in the system follow this procedure to use the duress function 1 Present your card at the reader skip this step if you are using mode 2 2 Key in your PIN or the main password if mode 2 immediately followed by the digit 9 Example 55559 followed by 3 The door will open normally access granted and the relay will activate for the pre set period of time How to use the D...

Page 33: ...Programming IoPass Step by Step Resetting the IoPass Unit to Factory Defaults 33 ...

Page 34: ...Programming IoPass Step by Step Resetting the IoPass Unit to Factory Defaults 34 ...

Page 35: ......

Page 36: ...ee US Canada 1 888 222 1560 Fax 1 978 731 7759 Web Site www Kantech com E mail techlink tycoint com 2003 Kantech Systems All rights reserved Specifications may be modified without notice Trademarks of Kantech Systems Printed in USA DN1445 0303 ...

Reviews: