P r o g r a m m i n g I o P a s s ™ - S t e p b y S t e p
- Managing Passwords
18
5.3.2 - Modifying the Main Password
The main password is a “global” password that can be used
when
Access mode “2”
is selected. This access mode
offers two options:
•
Users present the card to the reader, OR
•
They enter the main password to gain access.
To Modify the Main Password:
1.
Enter the master password (default is [111111]) then
[#]. The LCD displays the following:
1. ENROLL
2. PASSWD
3. TIMER
4. SYSTEM
2.
Press [2-Passwd]. The LCD displays the following:
1. MASTER
2. MAIN
3. AUX.CR
4. GUARD
3.
Press [2-Main]. The LCD displays the default Main
password:
Current: 1234
New:
4.
Enter the new main password. This password must be
4 characters.
5.
Press [#] to save and exit.
5.3.3 - Modifying the Auxiliary Password
The auxiliary password is used to activate an auxiliary
relay when the auxiliary function is enabled in the IoPass
unit.
You can either use the auxiliary card OR the auxiliary
password to activate the auxiliary relay.
To Modify the Auxiliary Password:
1.
Enter the master password (default is [111111]) then
[#]. The LCD displays the following:
1. ENROLL
2. PASSWD
3. TIMER
4. SYSTEM
2.
Press [2-Passwd]. The LCD displays the following:
1. MASTER
2. MAIN
3. AUX.CR
4. GUARD
3.
Press [3-Aux.Cr]. The LCD displays the default
password and invites you to enter a new one:
Current: 1234567
New:
4.
Enter the new auxiliary password. This password
must be 7 characters.
5.
Press [#] to save and exit.
5.3.4 - Modifying the Guard Password
The guard password is used to arm or disarm the connected
security system when the guard function is enabled. The
Guard password is automatically enabled when you enable
the guard function.
To Modify the Guard Password
1.
Enter the master password (default is [111111]) then
[#]. The LCD displays the following:
1. ENROLL
2. PASSWD
3. TIMER
4. SYSTEM
2.
Press [2-Passwd]. The LCD displays the following:
1. MASTER
2. MAIN
3. AUX.CR
4. GUARD
3.
Press [4-Guard]. The LCD displays the default
password and invites you to enter a new one:
Current: 123
New:
4.
Enter the new guard password. This password must
be 3 characters.
5.
Press [#] to save and exit.
Summary of Contents for IoPass SA-500
Page 4: ......
Page 6: ...vi ...
Page 12: ...Installing and Wiring IoPass Connecting the Power 12 General Wiring Diagram ...