P r o g r a m m i n g I o P a s s ™ - S t e p b y S t e p
- Configuring the Forced Entry Alarm
24
5.10.2 - Using the Tamper Alarm Function
Once the function is enabled in the system, follow this
procedure to STOP the tamper alarm if it has been
activated.
1.
When the tamper alarm has been activated, the alarm
relay will be triggered (usually an annunciator) and
the LCD will display:
READY FOR CARD
TAMPER ALARM (blink)
2.
This “Tamper Alarm” message is displayed (and
blinking) and will remain on the LCD until an
“access granted” operation is processed by the unit;
3.
Present your card and enter your PIN or master
password (depending on the system set up), access
will be granted and the message will disappear.
5.11
Configuring the Forced Entry Alarm
This function,
already enabled in the unit (default)
, will
automatically activate the “Alarm Relay” when the door
contact detects unauthorized access (without card or
password or both), a “door forced open” type of event.
Recommended Configuration Procedure
• Since this function is already enabled in the unit, follow
the procedure below if you need to disable it (not
recommended);
• Modify alarm relay timer activation (if required). See
“5.16 Alarm Relay Timer Configuration”, page 26 for
more information.
5.11.1 - Enabling/Disabling the Force Entry Alarm
Function
1.
To enter the programming mode, enter the master
password (default is [111111]) followed by the [#]
key. The LCD displays the following:
1. ENROLL
2. PASSWD
3. TIMER
4. SYSTEM
2.
Press [4-System]. The LCD displays:
1.ALARM
2.CHECK
3.MODE
4.OTHER
3.
Press [1-Alarm]. The LCD displays:
1.TAMPER 2.FORCE
3.D_AJAR 4.P_ERR
4.
Press [2-Force]. The LCD displays:
CURRENT: ENABLE
PRESS ’1’ --> CHANGE
5.
Press [1] until desired mode is displayed. Pressing
this key will toggle between selections. When
required mode is displayed, press [#] to save and exit.
5.11.2 - Using the Force Entry Function
Follow this procedure to STOP the force entry alarm if it
has been activated.
1.
When the force entry has been activated, the alarm
relay will be triggered (usually an annunciator) and
the LCD will display:
READY FOR CARD
FORCE ENTRY
2.
This “Force Entry” message is displayed (and
blinking) and will remain on the LCD until an
“access granted” operation is processed by the unit;
3.
Present your card and enter your PIN or master
password (depending on the system set up), access
will be granted and the message will disappear.
5.12
Configuring the Door Ajar Function
This function, already enabled in the unit (default),
can
activate the “Alarm relay” when the door is opened longer
than the pre-set time following an access granted
operation.
By default, the IoPass warning device will sound until the
door is closed correctly.
The user can decide if the alarm relay needs to be activated
when this situation occurs.
5.12.1 - Enabling/Disabling the Door Ajar Func-
tion
To enable/disable the door ajar function:
1.
Enter the master password (default is [111111]) fol-
lowed by the [#] key. The LCD displays the follow-
ing:
1. ENROLL
2. PASSWD
3. TIMER
4. SYSTEM
2.
Press [4-System]. The LCD displays:
1.ALARM
2.CHECK
3.MODE
4.OTHER
3.
Press [1-Alarm]. The LCD displays:
1.TAMPER 2.FORCE
3.D_AJAR 4.P_ERR
4.
Press [3-D_Ajar]. The LCD displays:
1.DOOR TIMER
2.ALARM RELAY
5.
Press [1-Door Timer] to enable or disable the door
ajar function. The LCD displays:
CURRENT: ENABLE
PRESS ’1’ --> CHANGE
6.
Press [1] until desired mode is displayed. Pressing
this key will toggle between selections. When
required mode is displayed, press [#] to save and exit.
7.
If you want the alarm relay to be activated when a
“door ajar” situation occurs, follow the procedure
below.
Summary of Contents for IoPass SA-500
Page 4: ......
Page 6: ...vi ...
Page 12: ...Installing and Wiring IoPass Connecting the Power 12 General Wiring Diagram ...
Page 14: ...Programming IoPass Introduction IoPass Factory Defaults 14 ...
Page 33: ...Programming IoPass Step by Step Resetting the IoPass Unit to Factory Defaults 33 ...
Page 34: ...Programming IoPass Step by Step Resetting the IoPass Unit to Factory Defaults 34 ...
Page 35: ......