P r o g r a m m i n g I o P a s s ™ - S t e p b y S t e p
- Beeper Key Tone Configuration
26
1. ENROLL
2. PASSWD
3. TIMER
4. SYSTEM
2.
Press [4-System]. The LCD displays:
1.ALARM
2.CHECK
3.MODE
4.OTHER
3.
Press [4-Other]. The LCD displays:
1.TONE
2.DURESS
3.MORE
4. LANGUAGE
4.
Press [3-More]. The LCD displays:
1.GUARD
2.AUX.CARD
3.A_DEL
4.RESET
5.
Press [3-A_Del]. The LCD displays:
CURRENT: DISABLE
PRESS ’1’ --> CHANGE
6.
Press [1] until desired mode is displayed. Pressing
this key will toggle between selections. When
required mode is displayed, press [#] to save and exit.
5.14
Beeper Key Tone Configuration
This function, already enabled in the unit (default),
provides an audible “beep” tone when the keys of the
keypad are used.
This function is convenient when the cardholder must key
in his PIN.
To disable the beeper:
1.
Enter the master password (default is [111111]) fol-
lowed by the [#] key. The LCD displays the follow-
ing:
1. ENROLL
2. PASSWD
3. TIMER
4. SYSTEM
2.
Press [4-System]. The LCD displays:
1.ALARM
2.CHECK
3.MODE
4.OTHER
3.
Press [4-Other]. The LCD displays:
1.TONE
2.DURESS
3.MORE
4. LANGUAGE
4.
Press [1-Tone]. The LCD displays:
CURRENT: ENABLE
PRESS ’1’ --> CHANGE
5.
Press [1] until desired mode is displayed. Pressing
this key will toggle between selections. When
required mode is displayed, press [#] to save and exit.
5.15
Loop Type Configuration
The IoPass unit allows the installer to modify the loop type
of the exit button and door contact.
These normally open contacts can be modified to normally
closed to suit installer’s requirements.
To configure the loop type:
1.
Enter the master password (default is [111111]) fol-
lowed by the [#] key. The LCD displays the follow-
ing:
1. ENROLL
2. PASSWD
3. TIMER
4. SYSTEM
2.
Press [4-System]. The LCD displays:
1.ALARM
2.CHECK
3.MODE
4.OTHER
3.
Press [3-Mode]. The LCD displays:
1.ACCESS MODE
2.DOOR_INPUT
4.
Press [2-Door_Input]. The LCD displays:
1.EXIT BUTTON
2.DOOR
5.
Press [1-Exit Button] to modify the exit button’s
polarity OR press [2-Door] to modify the door
contact’s polariy. In either cases, the LCD displays:
CURRENT: NC
PRESS ’1’ --> CHANGE
6.
Press [1] until desired mode is displayed. Pressing
this key will toggle between selections. When
required mode is displayed, press [#] to save and exit.
5.16
Alarm Relay Timer Configuration
By default, the alarm relay is pre-set to 240 seconds,
meaning that the connected annunciator will remain
activated for that period of time.
The timer can be modified from 1-255 seconds.
The alarm relay can be activated by the following events:
• Tamper alarm (if enabled);
• Forced entry (enabled by default);
• Door ajar (if enabled);
• Incorrect password keyed in five times consecutively
within four (4) minutes (if enabled).
NOTE:
This relay is always “enabled”, but options that can
trigger this relay can be customized by the user.
To configure the relay timer:
1.
Enter the master password (default is [111111]) fol-
lowed by the [#] key. The LCD displays the follow-
ing:
1. ENROLL
2. PASSWD
3. TIMER
4. SYSTEM
2.
Press [3-Timer]. The LCD displays:
1.STRIKE 2.ALARM
Summary of Contents for IoPass SA-500
Page 4: ......
Page 6: ...vi ...
Page 12: ...Installing and Wiring IoPass Connecting the Power 12 General Wiring Diagram ...
Page 14: ...Programming IoPass Introduction IoPass Factory Defaults 14 ...
Page 33: ...Programming IoPass Step by Step Resetting the IoPass Unit to Factory Defaults 33 ...
Page 34: ...Programming IoPass Step by Step Resetting the IoPass Unit to Factory Defaults 34 ...
Page 35: ......