53
PRESSURE SETTINGS
Before adjusting anything on the trencher valve check all main pressure settings as outlined in
chapter ‘Service Tasks - Hydraulics’ from the Operators Manual.
With the same setup as outlined there: hydraulic oil warmed up, pressure gauge (0-300 bar / 0-4300
PSI) plugged into test point, engine running at full speed (3600 rpm) do the following:
Over Centre Valve (3) Setting
Flow Control Valve (1) fully closed (turned clockwise).
Aux. Lever on main control valve
down
(trencher chain running forward).
The pressure should be set at:
69 – 76 bar (1000-1100 PSI) on all models.
Sequence Valve (4) Setting
Flow Control Valve (1) fully closed (turned clockwise).
Aux. Lever on main control valve up (trencher chain running backwards).
The pressure should be set at:
203 bar (2950 PSI)
on B Series Diesel Models
Checking Trenching Valve Function
• With trencher above ground and chain running forward
(Aux Lever (A) down)
pull both drive
levers backwards (to reverse Loader) and then start opening
Flow Control valve (1)
slowly.
• The loader should start moving backwards.
• The more the valve is opened the faster the loader should move.
Sequence Valve (4)
Overcentre Valve (3
)
Flow Control (1)
A
Summary of Contents for 8D Series
Page 1: ...8D SERIES OPERATOR S MANUAL WWW KANGALOADER COM 1300 4 KANGA PM 000130 ...
Page 2: ......
Page 69: ...69 DIMENSIONS 8 SERIES ...
Page 74: ......
Page 75: ......