28
29
EN
Juice Dispenser FSD3000 / FSD3100
© K. & M. Holland GmbH
© K. & M. Holland GmbH
Juice Dispenser FSD3000 / FSD3100
EN
Subject to technical change without prior notice! Version 4.0, 12/2017
Subject to technical change without prior notice! Version 4.0, 12/2017
8.1 Digital thermostat LAE AT1-5
Displays
During normal operation, the display indicates the measured temperature or one of the fol-
lowing variables:
DEF
Defrosting in process
HI
Excessive temperature alarm inside the cell
REC
SW restore after defrosting
LO
Low temperature alarm inside the cell
OFF
Controller in standby mode
E1
Sensor T1 defective
CL
Cleaning of the refrigerant condenser required
E2
Sensor T2 defective
DO
Open door alarm
Display and change of the set point – default temperature
1
Press and keep pressed
ð
default temperature will be displayed.
2
Use
or
to change the default temperature.
3
In order to leave the menu, wait 10 seconds.
Activating/deactivating key lock
1
Briefly press
ð
is displayed.
2
Press once
ð
LOC is displayed.
3
Press and keep pressed
. In order to activate or deactivate, repeatedly press
or
until the controller displays YES or NO.
Switching the controller on and off
1
Press
for at least 3 seconds
ð
the controller switches to ON (normal operation).
2
Use
to switch OFF the operation (keep key depressed for 3 seconds).
Manual defrosting
1
Press
for at least 2 seconds.
ð