GENERAL INSTRUCTIONS

The system and installation must comply with all state and local laws
and regulations.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system.
System conforms to NSF/ANSI 42 for the specific performance claims
as verified and substantiated by test data.

PERFORMANCE DATA

Flow Rate: ......................................................... 1.0 GPM (3.8 LPM)
Min./Max. Operating Pressure ............25 psi/125 psi (172 - 862 kPa)
Min./Max. Operating Temperature .................35°F/100°F (2°C/38°C)
Replacement Cartridge ...........................................GACI-SS Series A
Capacity .................................................2,000 Gallons (7,570 Liters)

NOTICES

Install this filter on a cold water line only. Use in ambient temper-
atures of between 35° and 100°F (2°-38°C) and with water tem-
peratures between 35° and 100°F (2° - 38°C). Water pressure
maximum is 125 psi (862 kPa).

Protect the unit from direct sunlight and freezing temperatures.

Do not use pipe dope or similar compounds. They can ruin plas-
tic. Use Teflon™ tape to seal pipe thread joints.

Intended for indoor, non-commercial use only.

For extended periods of non-use turn the water off and remove
the filter cartridge. Place the cartridge in a plastic bag, seal it,
and refrigerate it.

Safety glasses must be worn during installation.

This unit is not designed to filter sulfur (rotten egg odor). Use
of carbon filters to treat sulfur may intensify taste and odor
problems.

Before using the water, flush the  new filter for 30 minutes.

Run drinking or cooking water for 10 seconds prior to collecting
the water for use.

The contaminants effected by this filtering system are not neces-
sarily present in your water.

This filter is not a water purifier and is not intended for use with
contaminated water.

Comply with all state and local laws regarding the installation of
water treatment devices.

Use only OMNI filter cartridges with this housing, or warranty is
void.

“Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.” 

For conditions of use, health claims, and replacement parts, see
the performance data sheet.  Follow the instructions in this man-
ual to ensure unit performance.

When to change the filter cartridge

The GACI-SS Series A Cartridge should be changed after 2,000 
gallons of water use or every 6 months (whichever comes first).

TM

EI DU PONT DE NEMOURS and Company Corporation, Wilmington Delaware.

INSTALLATION INSTRUCTIONS

Choose and Mark Location:

1.Choose a location and position the filter housing bracket on the

wall of the cabinet nearest the cold water line beneath the sink.
Leave a 3” minimum clearance between the bottom of the filter
housing and the floor of the cabinet. See Figure 1.

2. Mark the bracket slots on the wall, drill a hole at each of the two

marks, and insert the mounting screws. Leave each screw head
1/4” out from the wall. Install the filter assembly onto the
mounting screws.

3. Locate and turn off the cold water inlet valve. 
4. Put a pan under the cold water valve and disconnect the cold

water pipe or tubing from the inlet valve. See Figure 2.

®

293 Wright St. • Delavan, WI 53115

Phone: 1-800-937-6664    
www.omnifilter.com

Undersink Water

Filter System

INSTALLATION INSTRUCTIONS

Model SFM2 Series A

Put a Pan Under the
Cold Water Pipe
or Tubing to
Collect the Water
from the Pipe.  
Disconnect the
pipe or Tubing. 

Figure 2

©2004, Omnifilter  Printed in U.S.A.  1000001406 (Rev. 6/14/04)

3"

Minim

um Required

Ver

tical Clear

ance

Choose the Housing
Location and Mark
the Screw Locations

Close the Cold
Water Inlet Valve

Locate
the Cold
Water
Line

Mounting

Scre

ws

1/4"

Figure 1

Summary of Contents for SFM2 Series A

Page 1: ...ter Comply with all state and local laws regarding the installation of water treatment devices Use only OMNI filter cartridges with this housing or warranty is void Do not use with water that is micro...

Page 2: ...s 10 Open the cold water shut off valve slowly Depress the pressure relief button on the top of the unit to release excess air See Figure 7 Check for leaks at all the fittings If there is a leak close...

Page 3: ...iltrer des eaux contamin es Se conformer tous les r glements en vigueur dans la province et dans la municipalit concernant l installation de tout dispositif de traitement de l eau Dans cette cuve n ut...

Page 4: ...p ration 11 Ouvrir le robinet d arriv e d eau froide et laisser l eau couler pendant 30 minutes Ceci permettra de chasser toutes les particules de fines et tous les morceaux de la cartouche filtrante...

Page 5: ...cartuchos de filtro OMNI con esta envoltura o la garant a quedar anulada No lo use con agua que presente peligros microbiol gicos o cuya calidad se desconozca sin una desinfecci n adecuada antes o des...

Page 6: ...pita el procedimiento desde el comienzo de este paso 11 Abra el grifo de agua fr a y deje correr el agua por 30 minutos Esto enjua gar toda part cula fina de material de filtro suelto fuera del cartuc...

Page 7: ...midero 1 5 Accesorios de compresi n de 3 8 3 8 2 6 Inserci n de lat n de 3 8 4 7 Camisa de compresi n de 3 8 4 8 Tuerca de compresi n de 3 8 4 9 Tuber a de polietileno de 3 8 2 10 Accesorio del grifo...

Page 8: ...8...

Reviews: