KPS SERIES
Installation
M-UK-KPS--06
11/02/03 Page 44 of 138
KALTENBACH
3.6
Safety
•
Set up
-
Only qualified skilled persons may setup , assemble, install electric and
hydraulic and commission the machine and periphery systems
-
Use qualified lifting and hoisting equipment
-
drill and periphery systems to be lifted through the suspension points only, if
provided. With forklift or hand truck only the supporting parts may be used for
hoisting.
DANGER
NEVER WALK OR STAND UNDER A HOISTED LOAD.
THIS CAN LEAD TO DEAD OR SERIOUS INJURY, IN CASE
THE LOAD WILL BREAKE LOOSE! NEVER ENTER A HOISTED
LOAD!
-
mechanical setup must be completed before the electric and hydraulic
connections can be made
•
Disassemble
-
Disconnect the machine from the electric main supply and air supply
-
Pump out the cooling fluid and discharge.
-
Clean the machine free of punch waste, chips, Dirt and cooling fluid.
-
Disconnect the electric, hydraulic and air connections from the periphery
systems.
-
Label these points before disconnection.
-
Blind stop the hydraulic tubes and connections.
-
Mount the transport bar and, if removed, mount the two transport supports on
the drill machine.
-
Unscrew the nuts from the anchor bolts.