Optisure Remote User’s Manual
20
March 2018
OPERATION
Output select
Selects the output to be adjusted
Available input: Output 1, 2 or 3
Output type
Selects the type of analog output signal to use
Available input: 4-20mA, 0-20mA, 0-1V
Parameter
The parameter used to control the elected output
Available input: DP, Temperature, Pressure, %RH, ppm
V
, % Vol, g/kg, g/m
3
, T-DP
Minimum
The minimum output range for the selected parameter
Available input: Dependant on parameter
Maximum
The maximum output range for the selected parameter
Available input: Dependant on parameter
Table 8
Outputs Menu
3.2.4 Alarm
Figure 17
Alarm Screen
Parameter
The parameter used to control the alarm
Available input: DP, Temperature, Pressure, %RH, ppm
V
, % Vol, g/kg, g/m
3
, T-DP
Setpoint
Set point the selected parameter should exceed to trigger the alarm relay to activate
Available input: Dependant on parameter
Table 9
Alarm Menu