![KAESER KCT blue T Series Operator'S Manual Download Page 97](http://html1.mh-extra.com/html/kaeser/kct-blue-t-series/kct-blue-t-series_operators-manual_3180215097.webp)
Reciprocating compressor
SKK-03009.02
with
Co
nne
ctor
ca
ble
and
Pl
ug
Con
nec
tor
ca
ble
s.b.
c.
h
1~
-K71
7.3299.0
-K1
1
2
3
4
5
6
7
8
page
Bl.
Circuit diagram
single-phase
s.b.c. = supplied by customer
Fuse
s.b.c.
max. 16A
L1
N
PE
See operating manual for supply
cable cross-section and fusing
Main switch,
Fuse
s.b.c.
max. 16A
L1
N
PE
Pressure switch
MDR2
P
PE
option
Hour meter
1
2
3
4
5
6
Pressure switch
MDR 3 3-pole
P
Compressor motor
(with Overload protection)
PE
PUR (UL/CSA)
3G1,5mm²
Timer module
t
PUR (UL/CSA)
3G0,75mm²
Solenoid valve
M
Ersatz für:
Ersatz durch:
a
b
c
Änderung
Datum
Datum
Bearbeiter
Geprüft
Norm
Name
Ursprung:
1
1
25.01.2019
=
+
D
Sitter
Gegner
100-
240V~
short circuit proof
24V=
0,17A
T1
T2
T3
U
13 Annex
13.3 Electrical diagram
No.: 902350 00E
Operator manual Reciprocating compressor
KCT blue T
87
Summary of Contents for KCT blue T Series
Page 2: ...Original instructions KKW PDENT 2 10 en SBA DENTAL T ANLAGE 20190503 092636...
Page 6: ...Contents iv Operator manual Reciprocating compressor KCT blue T No 902350 00E...
Page 8: ...List of Illustrations vi Operator manual Reciprocating compressor KCT blue T No 902350 00E...
Page 10: ...List of Tables viii Operator manual Reciprocating compressor KCT blue T No 902350 00E...