![KAESER KCT blue T Series Operator'S Manual Download Page 28](http://html1.mh-extra.com/html/kaeser/kct-blue-t-series/kct-blue-t-series_operators-manual_3180215028.webp)
➤ Ensure sufficient and suitable lighting such that the display can be read and work carried out
comfortably and safely.
➤ Ensure accessibility so that all work on the machine can be carried out without danger or hin‐
drance.
➤ If installed outdoors, the machine must be protected from frost, direct sunlight, dust, rain and
splashing water.
➤ Do not operate in areas in which specific requirements with regard to explosion protection are
in force.
For instance, the requirements of ATEX directive 2014/34/EC "Equipment and Protective Sys‐
tems intended for use in Potentially Explosive Atmospheres".
➤ Ensure adequate ventilation.
➤ Place the machine in such a manner that the working conditions in its environment are not im‐
paired.
➤ Comply with limit values for ambient temperature and humidity.
➤ The intake air must not contain any damaging contaminants.
Damaging contaminants are for instance: explosive or chemically instable gases and vapours,
acid or base forming substances such as ammonia, chlorine or hydrogen sulphide.
➤ Do not position the machine in the warm exhaust air flow from other machines.
➤ Keep suitable fire extinguishing agents ready for use.
Commissioning, operation and maintenance
During commissioning, operation and maintenance you may be exposed to dangers resulting from,
e.g., electricity, pressure and temperature. Careless actions can cause accidents with severe ad‐
verse effects for your health.
➤ Maintenance work should be carried out by authorised personnel only.
➤ Wear close-fitting, flame-resistant clothing. Wear protective clothing as necessary.
➤ Switch off and lock out the power supply disconnecting (isolating) device and check that no
voltage is present.
➤ Check that there is no voltage on potential-free contacts.
➤ Close shut-off valves or otherwise isolate the machine from the compressed air network to en‐
sure that no compressed air can flow back into the machine.
➤ Fully vent all pressurised components and enclosures. Verify the absence of pressure using a
suitable measuring device (pressure gauge).
➤ Allow the machine to cool down.
➤ Do not open the cabinet while the machine is switched on.
➤ Do not open or dismantle any valves.
➤ Use only spare parts approved by KAESER for use in this machine.
➤ Carry out regular inspections:
for visible damages,
of safety installations,
of the EMERGENCY STOP control device,
of the power supply isolating device
of any components requiring monitoring.
➤ Pay particular attention to cleanliness during all maintenance and repair work. Cover compo‐
nents and openings with clean cloths, paper or tape to keep them clean.
➤ Do not leave any loose components, tools or cleaning rags on or in the machine.
➤ Components removed from the machine can still be dangerous.
Do not attempt to open or destroy any components taken from the machine.
3
Safety and Responsibility
3.5
Dangers
18
Operator manual Reciprocating compressor
KCT blue T
No.: 902350 00E
Summary of Contents for KCT blue T Series
Page 2: ...Original instructions KKW PDENT 2 10 en SBA DENTAL T ANLAGE 20190503 092636...
Page 6: ...Contents iv Operator manual Reciprocating compressor KCT blue T No 902350 00E...
Page 8: ...List of Illustrations vi Operator manual Reciprocating compressor KCT blue T No 902350 00E...
Page 10: ...List of Tables viii Operator manual Reciprocating compressor KCT blue T No 902350 00E...